 浏览型号PIC18F6390-I/PT的Datasheet PDF文件第289页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第290页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第291页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第292页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第294页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第295页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第296页浏览型号PIC18F6390-I/PT的Datasheet PDF文件第297页  
PIC18F6390/6490/8390/8490  
FIGURE 23-4:  
FSCM TIMING DIAGRAM  
Sample Clock  
Oscillator  
Failure  
Device  
Clock  
Output  
CM Output  
(Q)  
Failure  
Detected  
OSCFIF  
CM Test  
CM Test  
CM Test  
Note:  
The device clock is normally at a much higher frequency than the sample clock. The relative frequencies in this  
example have been chosen for clarity.  
23.4.3  
FSCM INTERRUPTS IN  
23.4.4  
POR OR WAKE FROM SLEEP  
POWER-MANAGED MODES  
The FSCM is designed to detect oscillator failure at any  
point after the device has exited Power-on Reset  
(POR) or low-power Sleep mode. When the primary  
device clock is EC, RC or INTRC modes, monitoring  
can begin immediately following these events.  
By entering a power-managed mode, the clock  
multiplexer selects the clock source selected by the  
OSCCON register. Fail-Safe Clock Monitoring of  
the power-managed clock source resumes in the  
power-managed mode.  
For oscillator modes involving a crystal or resonator  
(HS, HSPLL, LP or XT), the situation is somewhat  
different. Since the oscillator may require a start-up  
time considerably longer than the FCSM sample clock  
time, a false clock failure may be detected. To prevent  
this, the internal oscillator block is automatically con-  
figured as the device clock and functions until the  
primary clock is stable (the OST and PLL timers have  
timed out). This is identical to Two-Speed Start-up  
mode. Once the primary clock is stable, the INTRC  
returns to its role as the FSCM source.  
If an oscillator failure occurs during power-managed  
operation, the subsequent events depend on whether  
or not the Oscillator Failure Interrupt Flag is enabled. If  
enabled (OSCFIF = 1), code execution will be clocked  
by the INTOSC multiplexer. An automatic transition  
back to the failed clock source will not occur.  
If the interrupt is disabled, the device will not exit the  
power-managed mode on oscillator failure. Instead, the  
device will continue to operate as before, but clocked  
by the INTOSC multiplexer. While in Idle mode, sub-  
sequent interrupts will cause the CPU to begin  
executing instructions while being clocked by the  
INTOSC multiplexer.  
Note:  
The same logic that prevents false  
oscillator failure interrupts on POR, or  
wake from Sleep, will also prevent the  
detection of the oscillator’s failure to start  
at all following these events. This can be  
avoided by monitoring the OSTS bit and  
using a timing routine to determine if the  
oscillator is taking too long to start. Even  
so, no oscillator failure interrupt will be  
flagged.  
As noted in Section 23.3.1 “Special Considerations  
for Using Two-Speed Start-up”, it is also possible to  
select another clock configuration and enter an  
alternate power-managed mode while waiting for the  
primary clock to become stable. When the new power-  
managed mode is selected, the primary clock is  
disabled.  
© 2007 Microchip Technology Inc.  
DS39629C-page 291