 浏览型号PIC18F8490-I/PT的Datasheet PDF文件第288页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第289页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第290页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第291页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第293页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第294页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第295页浏览型号PIC18F8490-I/PT的Datasheet PDF文件第296页  
PIC18F6390/6490/8390/8490  
To use a higher clock speed on wake-up, the INTOSC  
23.4 Fail-Safe Clock Monitor  
or postscaler clock sources can be selected to provide  
a higher clock speed by setting bits, IRCF2:IRCF0,  
immediately after Reset. For wake-ups from Sleep, the  
INTOSC or postscaler clock sources can be selected  
by setting the IRCF2:IRCF0 bits prior to entering Sleep  
mode.  
The Fail-Safe Clock Monitor (FSCM) allows the  
microcontroller to continue operation in the event of an  
external oscillator failure by automatically switching the  
device clock to the internal oscillator block. The FSCM  
function is enabled by setting the FCMEN Configuration  
bit.  
The FSCM will detect failures of the primary or second-  
ary clock sources only. If the internal oscillator block  
fails, no failure would be detected, nor would any action  
be possible.  
When FSCM is enabled, the INTRC oscillator runs at  
all times to monitor clocks to peripherals and provide a  
backup clock in the event of a clock failure. Clock  
monitoring (shown in Figure 23-3) is accomplished by  
creating a sample clock signal, which is the INTRC out-  
put divided by 64. This allows ample time between  
FSCM sample clocks for a peripheral clock edge to  
occur. The peripheral device clock and the sample  
clock are presented as inputs to the Clock Monitor latch  
(CM). The CM is set on the falling edge of the device  
clock source, but cleared on the rising edge of the  
sample clock.  
23.4.1  
FSCM AND THE WATCHDOG TIMER  
Both the FSCM and the WDT are clocked by the  
INTRC oscillator. Since the WDT operates with a  
separate divider and counter, disabling the WDT has  
no effect on the operation of the INTRC oscillator when  
the FSCM is enabled.  
As already noted, the clock source is switched to the  
INTOSC clock when a clock failure is detected.  
Depending on the frequency selected by the  
IRCF2:IRCF0 bits, this may mean a substantial change  
in the speed of code execution. If the WDT is enabled  
with a small prescale value, a decrease in clock speed  
allows a WDT time-out to occur and a subsequent  
device Reset. For this reason, Fail-Safe Clock Monitor  
events also reset the WDT and postscaler, allowing  
them to start timing from when execution speed was  
changed and decreasing the likelihood of an erroneous  
time-out.  
FIGURE 23-3:  
FSCM BLOCK DIAGRAM  
Clock Monitor  
Latch (CM)  
(edge-triggered)  
Peripheral  
Clock  
S
C
Q
Q
INTRC  
Source  
÷ 64  
(32 μs)  
488 Hz  
(2.048 ms)  
23.4.2  
EXITING FAIL-SAFE OPERATION  
The Fail-Safe condition is terminated by either a device  
Reset or by entering a power-managed mode. On  
Reset, the controller starts the primary clock source  
specified in Configuration Register 1H (with any  
required start-up delays that are required for the oscil-  
lator mode, such as the OST or PLL timer). The  
INTOSC multiplexer provides the device clock until the  
primary clock source becomes ready (similar to a Two-  
Speed Start-up). The clock source is then switched to  
the primary clock (indicated by the OSTS bit in the  
OSCCON register becoming set). The Fail-Safe Clock  
Monitor then resumes monitoring the peripheral clock.  
Clock  
Failure  
Detected  
Clock failure is tested for on the falling edge of the  
sample clock. If a sample clock falling edge occurs  
while CM is still set, a clock failure has been detected  
(Figure 23-4). This causes the following:  
• the FSCM generates an oscillator fail interrupt by  
setting bit OSCFIF (PIR2<7>);  
• the device clock source is switched to the internal  
oscillator block (OSCCON is not updated to show  
the current clock source – this is the Fail-Safe  
condition); and  
The primary clock source may never become ready  
during start-up. In this case, operation is clocked by the  
INTOSC multiplexer. The OSCCON register will remain  
in its Reset state until a power-managed mode is  
entered.  
• the WDT is reset.  
During switchover, the postscaler frequency from the  
internal oscillator block may not be sufficiently stable for  
timing sensitive applications. In these cases, it may be  
desirable to select another clock configuration and enter  
an alternate power-managed mode. This can be done to  
attempt a partial recovery or execute a controlled shut-  
down. See Section 3.1.2 “Entering Power-Managed  
Modes” and Section 23.3.1 “Special Considerations  
for Using Two-Speed Start-up” for more details.  
DS39629C-page 290  