H-XS-1W&G-XS-1W
Series
OUTPUT CHARACTERISTICS
Parameter
Rated Power
1
Voltage Set Point
Line regulation
Conditions
TA=-40°C to 60°C
See tolerance envelope
High Vin to low Vin
10% load to rated load,xx03
Min.
Typ.
Max.
1
Units
W
1.0
10.0
7.0
6.0
5.0
10.0
6.0
6.0
6.0
250
1.2
15.0
10.0
10.0
7.0
15.0
10.0
10.0
10.0
%%
Load regulation
Single outputs
10% load to rated load,0505
10% load to rated load,0509,0512,0515
10% load to rated load,12xx
10% load to rated load,5V output types
%
Load regulation
Dual outputs
10% load to rated load,9V output types
10% load to rated load,12V output types
10% load to rated load,15V output types
%
Zero Load Power
All types
MW
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Conditions
Flash tested for 1 second
Viso=500VDC
Min.
5200
Typ.
Max.
Units
VDC
1
GΩ
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Dual output
70
Conditions
Single output
Min.
Typ.
45
Max.
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Case Tempetature above
All output types
Conditions
All output types
Min.
-40
-55
Typ.
Max.
60
130
33
Units
°C
TEMPERATURE DERATING GRAPH
TOLERANCE ENVELOPE
H-XS/G-XS-1W
3.3V in,3V out type only
1.See derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.Another 24V& 48V products, please inquire Our technical department!
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646