欢迎访问ic37.com |
会员登录 免费注册
发布采购

IA2405XS-2W 参数 Datasheet PDF下载

IA2405XS-2W图片预览
型号: IA2405XS-2W
PDF下载: 下载PDF文件 查看货源
内容描述: 定电压输入,隔离稳压双输出DC / DC转换器 [FIXED INPUT,ISOLATED & REGULATED Dual Output DC/DC Converters]
分类和应用: 转换器输入元件
文件页数/大小: 2 页 / 682 K
品牌: MICRODC [ MICRODC POWER TECHNOLOGY CO., LTD ]
 浏览型号IA2405XS-2W的Datasheet PDF文件第2页  
IA-XS-2W
Series
FIXED INPUT,ISOLATED & REGULATED Dual Output DC/DC Converters
SELECTION GUIDE
Input
Order code
Voltage(VDC)
Output
Range
Voltage
(VDC)
Current
Max
Min
Nominal
Efficiency
(%,Typ)
Switching
Frequency
(KHz,Typ)
IA0503XS-2W
IA0505XS-2W
5
5
5
5
5
12
12
12
12
24
24
24
24
4.75-5.25
4.75-5.25
4.75-5.25
4.75-5.25
4.75-5.25
11.4-12.6
11.4-12.6
11.4-12.6
11.4-12.6
22.8-25.2
22.8-25.2
22.8-25.2
22.8-25.2
±3.3
±5
±9
±12
±15
±5
±9
±12
±15
±5
±9
±12
±15
±150
±200
±100
±83
±67
±150
±100
±83
±67
±150
±100
±83
±67
±15
±20
±10
±9
±7
±15
±10
±9
±7
±15
±10
±9
±7
69
70
62
64
65
70
63
65
68
70
63
67
69
100
55
67
67
200
83
91
91
200
83
100
200
91
FEATURES
RoHS compliant
Efficiency up to 86%
SIP Package
Wide temperature performance at full
IA0509XS-2W
IA0512XS-2W
IA0515XS-2W
IA1205XS-2W
IA1209XS-2W
IA1212XS-2W
IA1215XS-2W
IA2405XS-2W
IA2409XS-2W
IA2412XS-2W
IA2415XS-2W
2 Watt load,-40°C to 85°C
UL 94V-0 package material
No heatsink required
Small Footprint
Industry standard pinout
Power sharing on output
1KVDC isolation
3.3V,5V,9V,12V and 15V output
Internal SMD construction
No external components required
MTTF up to 1.5 million hours
ISOLATION SPECIFICATIONS
Parameter
Isolation test voltage
Isolation resistance
Test conditions
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Min.
1000
1000
Typ.
Max.
Units
VDC
MODEL SELECTION
IA
05
05
X
S
-2W
①Product
Series
③Output
Voltage
⑤SIP
Package
②Input
Voltage
④Fixed
Input
⑥Rated
Power
APPLICATIONS
The IA_XS-2W series are specially designed for applications
where a group of polar power supplies are isolated from the
input power supply in a distributed power supply system on a
circuit board.
These products apply to:
1) where the voltage of the input power supply is fixed
(voltage variation ≤±5%);
2) where isolation is necessary between input and output
(isolation voltage ≤1000VDC);
3) where the regulation of the output voltage and the output
ripple noise are demanded.
OUTPUT SPECIFICATIONS
Parameter
Output power
Line regulation
Load regulation
Output voltage accuracy
Temperature drift
Output Ripple*
Output Noise*
For Vin change of ±5%
10% to 100% full load
100% full load
100% full load
20MHz Bandwidth
20MHz Bandwidth
20
75
Test conditions
Min
0.2
Typ.
Max.
2
±0.25
±1
±3
0.03
30
150
Units
W
%
%
%
%/°C
MV p-p
MV p-p
* Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC reserves the copyright
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 2