型号: MA2412XD-1W
PDF下载: 下载PDF文件 查看货源
内容描述: 1W / 2W ,定电压输入, ISOLA TED和稳压双输出DC- DC转换器 [1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER]
分类和应用: 转换器输出元件输入元件DC-DC转换器
文件页数/大小: 2 页 / 445 K
品牌: MICRODC [ MICRODC POWER TECHNOLOGY CO., LTD ]
 浏览型号MA2412XD-1W的Datasheet PDF文件第2页  
MA-XD-1W&MA-XD-2W
Series
1W/2W, FIXED INPUT , ISOLA TED & REGULATED DUAL OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Order code
Voltage(VDC)
Nominal
MA0512XD-1W
5
5
5
5
5
12
12
12
12
12
24
24
24
24
24
Range
4. 75-5.25
4. 75-5.25
4. 75-5.25
4. 75-5.25
4. 75-5.25
11. 4-12.6
11. 4-12.6
11. 4-12.6
11. 4-12.6
11. 4-12.6
22. 8-25.2
22. 8-25.2
22. 8-25.2
22. 8-25.2
22. 8-25.2
Voltage
(VDC)
±12
±15
±9
±12
±15
±12
±15
±9
±12
±15
±12
±15
±9
±12
±15
Output
Current(mA)
Max.
±42
±33
±100
±83
±67
±42
±33
±100
±83
±67
±42
±33
±100
±83
±67
Min.
±5
±4
±10
±9
±7
±5
±4
±10
±9
±7
±5
±4
±10
±9
±7
Efficiency
1
(%,Typ)
64
65
62
63
64
64
65
63
65
66
64
65
63
66
67
FEATURES
Low ripple
Good dynamic feature
1KVDCIsolation
DIP24 Package
Temperature Range:-40℃ ~ +85
UL94-V0 Package
No Heatsink Required
No External Component Required
Internal SMD construction
RoHS Compliance
MA0515XD-1W
MA0509XD-2W
MA0512XD-2W
MA0515XD-2W
MA1212XD-1W
MA1215XD-1W
MA1209XD-2W
MA1212XD-2W
MA1215XD-2W
MA2412XD-1W
MA2415XD-1W
MA2409XD-2W
MA2412XD-2W
MA2415XD-2W
MODEL SELECTION
MA 05 12 -X D -2W(83)
①Product
Series
②Input
Voltage
③Output
Voltage
④Fixed
Input
⑤DIP24
Package Style
⑥Rated
Power(Output current)
ISOLATION SPECIFICATIONS
Parameter
Storage humidity
Isolation resistance
Test conditions
Tested for 1 minute and 1mA max
Test at 500VDC
Min.
1000
1000
Typ.
Max.
Units
VDC
MΩ
APPLICATIONS
The MA_XD-1W & MA_XD-2W Series are specially
designed for applications where a group of polar
power supplies are isolated from the input power
supply in a distributed power supply system on a
circuit board.
These products apply to:
1)
2)
3)
Where the voltage of the input power supply is fixed
Where isolation is necessary between input
Where the regulation of the output voltage and
and
the
(voltage variation≤±5%);
Output Noise*
Switching frequency
Output voltage accuracy
Temperature drift
2
Output ripple*
COMMON SPECIFICATIONS
Parameter
Line regulation
Test conditions
For Vin change of
±5%(1W&2W)
10% to 100% full load
100% full load
100% full load
20MHz Bandwidth(1W)
20MHz Bandwidth(2W)
20MHz Bandwidth(1W&2W)
Full load, nominal
input
Min
Typ.
Max.
±0.25
±1
±3
0.03
Units
%
%
%
%/℃
mVp-p
mVp-p
mVp-p
KHz
10
20
50
75
20
40
150
output (isolation voltage
≤1000VDC);
output ripple noise are demanded.
*Test ripple and noise by
parallel cable
met hod.See detailed operation instructions at Testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25℃, humidity<75%, nominal input voltage and rated output load
otherwise specified.
2. See below recommended circuits for more details.
unless
MICRODC reserves the copyright
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646