WRA-YGD-2W&WRB-YGD-2W
Series
2W,Wide Input Range SMD, Dual/Single Output DC/DC Converters
Converters
Absolute Maximum Ratings
Parameter
5VDC Input Models
Input Sure Voltage
(1000 mS)
12VDC Input Models
24VDC Input Models
48VDC Input Models
Min.
-0.7
-0.7
-0.7
-0.7
---
---
Max.
11
25
50
100
260
1,800
Unit.
VDC
VDC
VDC
VDC
℃
mW
FEATURES
◆
Ultra-wide 2:1 input range
◆
DIP-16 package
◆
Efficiency up to 81%
◆
Temperature range –40°C to +85°C
◆
HMTBF>1,000,000 Hours
◆
Low Ripple and Noise
◆
Short Circuit Protection
◆
I/O isolation 1500 VDC
◆
Complies with EN55022 Class A
◆
Fully RoHS compliant
◆
UL 94 V-0 Package Material
◆
Internal SMD Construction
Lead Temperature(1.5mm from case for 10 Sec.)
Internal Power Dissipation
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted
Conditions
Ambient
Case
Min.
-40
-40
-40
---
Free-Air Convection
EN55022 Class A
Max.
+65
+90
+125
95
Unit.
℃
℃
℃
%
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Capacitive Load
Models by Vout
Maximum Capacitive Load
* For each output
3.3V
2200
5V
1000
12V
110
15V
470
±5V
*
100
±12V
*
20
±15V*
47
Unit
uF
MODEL SELECTION
WRA
①
24
②
05
③
Y
④
GD
⑤
-2W(119)
⑥
①Product
Series
②Input
Voltage
③Output
Voltage
④Wide
(2:1) Input Range
⑤DIP16
Package Style
⑥Rated
Power(Output current)
Input Fuse Selection Guide
5V Input Models
1000mA Slow - Blow Type
12V Input Models
500mA Slow - Blow Type
24V Input Models
250mA Slow - Blow Type
48V Input Models
120mA Slow - Blow Type
DESCRIPTION
The WRA-YGD-2W & WRB-YGD-2W Series power modules
are low-profile dc-dc converters that operate over input voltage of
4.5-9VDC,9-18VDC,18-36VDC and 36-75VDC
and
±15VDC.
The WRA-YGD-2W & WRB-YGD-2W Series is an excellent for
data
communication
equipments,mobile
power
battery
driven
equipments,distributed
systems,telecommunication
which provide
precisely regulated output voltages of 3.3V,5V,12V,15V,±5V,±12V
equipments,mixed analog/machine control equipments,computer
peripheral systems and industrial robot systems.
The modules have a maximum power rating of 2W and a typical
full-load efficiency of 81%,continuous short circuit,30mV output
ripple,built-in filtering for both input and output minimize the need
for external filtering.
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 6