WRA-YMD-6W
&
WRB-YMD-6W
Series
WIDE INPUT,ISOLATED & REGULATED Dual/Single Output DC/DC Converter
SELECTION GUIDE
Input
order code
Nominal
Voltage(VDC)
Range
Max*
Output
Current(MA)
Max
Min
Voltage
(VDC)
(%,Typ)
Efficiency
WRA0505YMD-6W
5
5
5
5
5
5
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
4.5-9.0
4.5-9.0
4.5-9.0
4.5-9.0
4.5-9.0
4.5-9.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
11
11
11
11
11
11
20
20
20
20
20
20
20
40
40
40
40
40
40
40
40
80
80
80
80
80
80
80
80
±600
±250
±200
1200
500
400
±600
±250
±200
1200
500
400
250
±600
±250
±200
1500
1200
500
400
250
±600
±250
±200
1500
1200
500
400
250
±60
±25
±20
120
50
40
±60
±25
±20
120
50
40
25
±60
±25
±20
150
120
50
40
25
±60
±25
±20
150
120
50
40
25
±5
±12
±15
5
12
15
±5
±12
±15
5
12
15
24
±5
±12
±15
3.3
5
12
15
24
±5
±12
±15
3.3
5
12
15
24
75
80
82
76
80
82
79
82
84
79
82
84
82
81
84
86
78
80
84
86
85
80
84
85
78
80
84
86
85
FEATURES
◆
RoHS compliant
◆
Efficiency up to 86%
◆
1"×1"DIP Package
◆
Wide temperature performance at full
WRA0512YMD-6W
WRA0515YMD-6W
WRB0505YMD-6W
WRB0512YMD-6W
WRB0515YMD-6W
WRA1205YMD-6W
WRA1212YMD-6W
WRA1215YMD-6W
WRB1205YMD-6W
WRB1212YMD-6W
WRB1215YMD-6W
WRB1224YMD-6W
WRA2405YMD-6W
WRA2412YMD-6W
WRA2415YMD-6W
6 Watt load,-40°C to 85°C
◆
UL 94V-0 package material
◆
No heatsink required
◆
Low ripple and good EMC Features
◆
Industry standard pinout
◆
Power sharing on output
◆
I/O Isolation 1500VDC
◆
Short Circuit Protection(
automatic recovery
)
◆
Metal case package
◆
MTBF>1000000 hours
WRB2403YMD-1500
WRB2405YMD-6W
WRB2412YMD-6W
WRB2415YMD-6W
WRB2424YMD-6W
WRA4805YMD-6W
WRA4812YMD-6W
WRA4815YMD-6W
WRB4803YMD-1500
MODEL SELECTION
①
②
③ ④
⑤
⑥
⑦
WRB 24 05 Y M D -6W(1200)
WRB4805YMD-6W
WRB4812YMD-6W
WRB4815YMD-6W
WRB4824YMD-6W
①Product
Series
②Input
Voltage
③Output
Voltage
④Wide
(2:1) Input Range
⑤Metal
Shield
⑥1"×1"DIP
Package
⑦Rated
Power(Output current)
*Input voltage can't exceed this value,or will cause the permanent damage.
DESCRIPTION
The WRA_YMD-6W& WRB_YMD-6W series are specially
designed for applications where a group of polar power
supplies are isolated from the input power supply in a
distributed power supply system on a circuit board.
These products apply to:
1) where the voltage of the input power supply is wide
range (voltage range ≤2:1);
2) where isolation is necessary between input and output
(isolation voltage ≤1500VDC);
3) where the regulation of the output voltage and the
output ripple noise are demanded.
OUTPUT SPECIFICATIONS
Parameter
Test conditions
Min.
Typ.
Max.
Units
Output power
Positive voltage accuracy
Negative voltage accuracy
Load regulation
Line regulation(at full load)
Temperature drift(Vout)
Output Ripple**
Output Noise**
Switching frequency
See above products program
Refer to recommended circuit
Refer to recommended circuit
From 10% to 100% full load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
20MHz Bandwidth
100% Full load,input voltage range
0.6
±1.0
±3.0
±0.5
±0.2
6
±3.0
±5.0
±1.0
±0.5
±0.03
20
50
300
50
100
W
%
%
%
%
%/°C
MV p-p
MV p-p
Khz
* Dual output models unbalanced load (25/100%):±5%Max
* *Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC reserves the copyright
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3