WRA-ZD-8W
&
WRB-ZD -8W
Series
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
FOOTPRINT DETAILS
RECOMMENDED FOOTPRINT
Top view grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
TUBE OUTLINE DIMENSIONS
Pin
2、3
9
11
14
16
22、23
NC:No connection
Single
GND
NC
NC
+Vo
0V
Vin
Dual
GND
0V
-Vo
+Vo
0V
Vin
When the environment temperature is higher than
71 , the product output power should be less
71℃,
then 60% of the rated power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening
output pin (0V) to use as single output.
Note:
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 15pcs
L=220mm[8.661inch] Tube Quantity: 6pcs
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
page 3/4