53111
Power MOSFET Optocoupler
ELECTRICAL SPECIFICATIONS
TA = -55°C to +125°C, unless otherwise specified.
Parameter
Sym.
Min.
Typ.*
Max.
Units
Test Conditions
VF = 0.6 V
IO = 10 µA
Notes
Output Withstand Voltage VO(OFF)
90
110
V
IF = 10 mA (for –01)
IF = 5 mA (for –02)
IO = 800 mA
Output On-Resistance
(Connection A)
0.40
1.0
Ω
Ω
(pulse duration ≤ 30 ms)
3,
R(ON)
Figure
IF = 10 mA (for –01)
IF = 5 mA (for –02)
IO = 1.6 A
1
Output On-Resistance
(Connection B)
0.12
0.25
(pulse duration ≤ 30 ms)
VF = 0.6 V
Output Leakage Current
Input Forward Voltage
IO (OFF)
VF
10-4
10
µA
V
VO = 90 V
IF = 10 mA (for –01)
IF = 5 mA (for –02)
1.0
5.0
1.24
1.7
Input Reverse Breakdown
Voltage
VR
V
IR = 100 µA
RH ≤ 45%, t = 5 s
VI-O = 1500 VDC
TA = 25°C
IF = 10 mA (for –01)
IF = 5 mA (for –02)
Input-Output Insulation
II-O
1.0
6.0
4, 5
µA
Figure
6
Turn-On Time
tON
1.25
0.02
ms
V
DD = 28 VDC
IO = 800 mA
IF = 10 mA (for –01)
IF = 5 mA (for –02)
VDD = 28 VDC
IO = 800 mA
Figure
6
Turn-Off time
tOFF
0.25
ms
VPEAK = 50 V
CM = 1000 pF
CL = 15 pF
RM ≥ 1 MΩ
Output Transient
Rejection
Figure
7
dVO/dt
dVI-O/dt
1000
500
V/µs
V/µs
V
DD = 5 V
V
I-O (PEAK) = 50 V
Input-Output Transient
Rejection
Figure
8
RL = 20 kΩ
CL = 15 pF
* All typical values are at TA = 25ºC, IF (ON) = 10 mA (for -01) or 5 mA (for –02), VF (OFF) = 0.6V unless otherwise
specified.
Micropac Industries cannot assume any responsibility for any circuits shown or represent that they are free from patent infringement.
Micropac reserves the right to make changes at any time in order to improve design and to supply the best product possible.
MICROPAC INDUSTRIES, INC. MICROCS PRODUCTS DIVISION • 905 E. Walnut St., Garland, TX 75040 • (972) 272-3571 • Fax (972) 494-2281
www.micropac.com
E-MAIL: hybridsales@micropac.com
5/22/02
Pg. 3 of 11