欢迎访问ic37.com |
会员登录 免费注册
发布采购

XM1003-BD-EV1 参数 Datasheet PDF下载

XM1003-BD-EV1图片预览
型号: XM1003-BD-EV1
PDF下载: 下载PDF文件 查看货源
内容描述: 32.0-42.0 GHz的砷化镓MMIC镜像抑制混频器 [32.0-42.0 GHz GaAs MMIC Image Reject Mixer]
分类和应用:
文件页数/大小: 7 页 / 397 K
品牌: MIMIX [ MIMIX BROADBAND ]
 浏览型号XM1003-BD-EV1的Datasheet PDF文件第2页浏览型号XM1003-BD-EV1的Datasheet PDF文件第3页浏览型号XM1003-BD-EV1的Datasheet PDF文件第4页浏览型号XM1003-BD-EV1的Datasheet PDF文件第5页浏览型号XM1003-BD-EV1的Datasheet PDF文件第6页浏览型号XM1003-BD-EV1的Datasheet PDF文件第7页  
32.0-42.0 GHz GaAs MMIC
Image Reject Mixer
February 2008 - Rev 06-Feb-08
M1003-BD
Chip Device Layout
Features
Sub-harmonic Image Reject Mixer
GaAs HBT Technology
9.0 dB Conversion Loss
18.0 dB Image Rejection
100% On-Wafer RF Testing
100% Visual Inspection to MIL-STD-883
Method 2010
XM1003-BD
General Description
Mimix Broadband’s 32.0-42.0 GHz GaAs MMIC
sub-harmonic image reject mixer can be used as an up-
or down-converter. The device has a conversion loss of
9.0 dB with 18.0 dB image rejection across the band. I and
Q mixer outputs are provided and an external 90 degree
hybrid is required to select the desired sideband. This
MMIC uses Mimix Broadband’s 2 µm GaAs HBT device
model technology, and is based upon electron beam
lithography to ensure high repeatability and uniformity.
The chip has surface passivation to protect and provide a
rugged part with backside via holes and gold
metallization to allow either a conductive epoxy or
eutectic solder die attach process. This device is well
suited for Millimeter-wave Point-to-Point Radio, LMDS,
SATCOM and VSAT applications.
Parameter
Frequency Range (RF) Upper Side Band
Frequency Range (RF) Lower Side Band
Frequency Range (LO)
Frequency Range (IF)
RF Return Loss (S11)
IF1/IF2 Return Loss (S22)
LO Return Loss (S33)
Conversion Loss (S21)
LO Input Drive (P
LO
)
Image Rejection
Isolation LO/RF
Isolation LO/IF
Isolation RF/IF
Input Third Order Intercept (IIP3)
Absolute Maximum Ratings
Input Power (RF Pin)
Input Power (IF Pin)
Storage Temperature (Tstg)
Operating Temperature (Ta)
+20 dBm
+20 dBm
-65 to +165
O
C
-55 to +125
O
C
Electrical Characteristics (Ambient Temperature T = 25
o
C)
Units
GHz
GHz
GHz
GHz
dB
dB
dB
dB
dBm
dBc
dBc
dB
dB
dBm
Min.
34.0
32.0
15.0
DC
-
-
-
-
-
-
-
-
-
-
Typ.
-
-
-
-
10.0
TBD
TBD
9.0
+12.0
18.0
-40.0
TBD
TBD
+14.0
Max.
42.0
42.0
23.0
4.0
-
-
-
-
-
-
-
-
-
-
Page 1 of 7
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Characteristic Data and Specifications are subject to change without notice.
©2008
Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.