AGF-10 Series
Model Selection Guide
Model
Number
Output Voltage
Output Current
Max.
mA
2500
2000
833
667
417
Min.
mA
250
200
83
67
42
Input Current
115VAC, 60Hz
@Max. Load
@No Load
mA (Typ.)
mA (Typ.)
171
15
201
15
191
15
193
15
201
15
Capacitive Load
Max.
uF
2200
2200
1000
1000
680
Efficiency
@Max. Load
% (Typ.)
70
72
76
75
72
AGF-10S03
AGF-10S05
AGF-10S12
AGF-10S15
AGF-10S24
VDC
3.3
5
12
15
24
Input Fuse Selection Guide
All Models
External Fuse (Recommended)
1.5A Slow - Blow Type
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Inrush Current (Cold Start at 25])
Model
All Models
115VAC
230VAC
Min.
90
47
---
---
Typ.
---
---
---
---
Max.
264
440
15
30
Unit
VAC
Hz
A
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Over Voltage Protection
Temperature Coefficient
Overshoot
Current limitation
Short circuit protection
85VAC, Hiccup technique, auto-recovery
Vin=Min. to Max.
Io=Min. to Max.
3.3 & 5.0VDC Output Models
Other Output Models
Zener diode clamp
Conditions
Min.
---
---
---
---
---
---
---
---
105
Typ.
{1.0
{0.5
{0.5
1.5
0.8
120
{0.01
---
---
Max.
{2.0
{1.0
{1.0
1.8
1.0
---
{0.02
5
---
Unit
%
%
%
%V
pp
of Vo
%V
pp
of Vo
% of Vo
%/]
%
%
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Switching Frequency
Hold-up Time
MTBF
115VAC, 60Hz
MIL-HDBK-217F @ 25], Ground Benign
Conditions
Input to Output, 60 Seconds
Input to output, Flash Tested for 1 Second
500VDC
Min.
3000
4700
100
---
---
330
Typ.
---
---
---
125
15
---
Max.
---
---
---
---
---
---
Unit
VAC
VDC
M[
KHz
ms
K Hours
REV:5 2009/02/16