AHF-10 SERIES
AC/DC POWER MODULE 10W
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
Conditions
Input to Output, 60 Seconds
500 VDC
Min.
Typ.
Max.
Unit
3000
---
---
VACrms
100
---
---
MΩ
---
100
---
KHz
---
20
---
ms
300,000
----
----
Hours
EN 55011, class B, EN 55022, class B, FCC part 15, class B
Specification Requirement
Performance Criteria
Air ±8KV Cont. ±4KV
B
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
AC port ±2KV DC, SL, TL ±2KV not less than 1 min.
B
1.2/50uS(8/20uS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports included)
B
80% AM, 1KHz modulation
50Hz/60Hz, 30A/m
A
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
EMC Immunity according
EN61000-6-1
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Protection Class II
Safety Approvals
Input Fuse
All Models
Built-in Fuse
External Fuse (Recommended)
2A / 250VAC
1.5A Slow – Blow Type
Environmental Specifications
Parameter
Temperature Range (operational)
Power Derating
Storage Temperature Range
Over Temperature Protection
Cooling
Humidity (non condensing)
Ambient
+50℃
to +70℃
Conditions
-25℃
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
+70℃
0.375W /
℃
+85℃
95 % rel. H
Notes
1
2
3
4
5
All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0~20 MHz
These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage the power
supplies however they may not meet all listed specifications.
Other input and output voltage may be available, please contact factory.
Specifications subject to change without notice
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/09/01 REV:12