DC/DC CONVERTER 1W,
SIP-Package
MAU100 SERIES
Input Specifications
Parameter
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Internal Filter Type
Internal Power Dissipation
Model
5V Input Models
12V Input Models
15V Input Models
24V Input Models
5V Input Models
12V Input Models
15V Input Models
24V Input Models
All Models
Min.
4.5
10.8
13.5
21.6
-0.7
-0.7
-0.7
-0.7
---
---
Typ.
Max.
5
5.5
12
13.2
15
16.5
24
26.4
---
9
---
18
---
18
---
30
---
0.3
Internal Capacitor
---
450
Unit
VDC
A
mW
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
max. 20MHz Bandwidth
Min.
---
---
---
---
---
Typ.
Max.
±1.0
±3.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
50
75
±0.01
±0.02
0.5 Second Max.
Unit
%
%
%
mV
P-P
%/℃
General Specifications
I/O Isolation Voltage (rated)
I/O Isolation Resistance
Switching Frequency
MTBF (calculated)
I/O Isolation Capacitance
Parameter
60 Seconds
100KHz, 1V
MIL-HDBK-217F@25℃, Ground Benign
500 VDC
Conditions
1000
70
---
1000
Min.
Typ.
---
---
Max.
---
---
VDC
M
pF
Unit
2,000,000
100
---
60
100
---
120
Hours
KHz
Input Fuse
500mA Slow-Blow Type
5V Input Models
200mA Slow-Blow Type
12V Input Models
150mA Slow-Blow Type
15V Input Models
100mA Slow-Blow Type
24V Input Models
Environmental Specifications
Case Temperature
Operating Ambient Temperature Range (See Power Derating Curve)
Storage Temperature Range
Humidity (non condensing)
Cooling
Parameter
Natural Convection
Conditions
Min.
-40
---
---
Max.
+85
+90
95
Unit
℃
℃
% rel. H
℃
℃
-50
Free-Air convection
---
+125
Lead Temperature (1.5mm from case for 10Sec.)
260
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2013/01/23 REV:4