欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAU307 参数 Datasheet PDF下载

MAU307图片预览
型号: MAU307
PDF下载: 下载PDF文件 查看货源
内容描述: DC / DC转换器2W SIP封装与国际标准引脚 [DC/DC CONVERTER 2W SIP Package with Industry Standard Pinout]
分类和应用: 转换器
文件页数/大小: 4 页 / 511 K
品牌: MINMAX [ MINMAX TECHNOLOGY CO., LTD. ]
 浏览型号MAU307的Datasheet PDF文件第1页浏览型号MAU307的Datasheet PDF文件第3页浏览型号MAU307的Datasheet PDF文件第4页  
DC/DC CONVERTER 2W,
SIP-Package
MAU300 SERIES
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
max. 20MHz Bandwidth
Min.
---
---
---
---
---
Typ.
Max.
±1.0
±3.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
100
150
±0.01
±0.02
0.5 Second Max.
Unit
%
%
%
mV
P-P
%/℃
General Specifications
I/O Isolation Voltage (rated)
I/O Isolation Resistance
Switching Frequency
MTBF (calculated)
I/O Isolation Capacitance
Parameter
60 Seconds
100KHz, 1V
MIL-HDBK-217F@25℃, Ground Benign
500 VDC
Conditions
1000
50
---
1000
Min.
Typ.
---
---
Max.
---
---
VDC
M
pF
Unit
80
---
2,000,000
80
120
---
100
Hours
KHz
Input Fuse
1000mA Slow-Blow Type
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
Environmental Specifications
Case Temperature
Operating Ambient Temperature Range (See Power Derating Curve)
Storage Temperature Range
Humidity (non condensing)
Cooling
Parameter
Conditions
Natural Convection
Min.
-40
---
---
Max.
+90
95
+85
Unit
% rel. H
-50
Free-Air convection
---
+125
Lead Temperature (1.5mm from case for 10Sec.)
260
Power Derating Curve
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2013/01/23 REV:4
Page 2 of 4
Output Power (%)