Test Setup
DC/DC CONVERTER 3W, DIP-Package
Peak-to-Peak Output Noise Measurement Test
MIAR03 SERIES
Us
e a Cout 0.33µF ceramic capacitor.
Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC
Converter.
+Vin
Single Output
DC / DC
Converter
-Vin
-Out
+Out
Copper Strip
Cout
Copper Strip
Resistive
Scope
Load
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Com.
-Out
Copper Strip
Cout
Copper Strip
Cout
Copper Strip
Scope
Scope
Resistive
Load
Technical Notes
The MIAR03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
Maximum Capacitive Load
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0 at 100 KHz) capacitor of a 4.7µF for the 5V input devices and a 2.2µF for the 12V and 24V devices.
+
DC Power
Source
-
+
Cin
-Vin
-Out
+Vin
DC / DC
Converter
+Out
Load
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.5µF capacitors at the output.
+
DC Power
Source
-
-Vin
+Vin
Single Output
DC / DC
Converter
-Out
+Out
+
DC Power
Source
-
+Vin
+Out
Dual Output
DC / DC Com.
Converter
Cout
Cout
Load
Load
Cout
Load
-Vin
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail:
sales@minmax.com.tw
Minmax Technology Co., Ltd.
2013/01/30 P5