MIHW3000 Series
5-6W, Ultra-High Isolation DIP, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 80%
2:1 Wide Input Range
5600VDC Isolation
Complies With EN55022 Class A
with external coupling capacitor Cio=1 nF < Class B
Low Leakage Current
Low Isolation Capacitance
All I/O Clearance and Creepage Distance 2.0 mm Min.
Temperature Performance -40] to +55]
MTBF > 700,000 Hours
UL60950-1 Safety Approval
2:1
Wide Range
EMI
EN55022
5600
VDC
I/O Isolation
Minmax's MIHW3000-Series power modules are specially designed to provide ultra-high levels of isolation 5600VDC in a 24-pin DIP package.
Operating input voltage ranges of 9-18VDC, 18-36VDC and 36-75VDC which provide precisely regulated output voltages of 5V, 12V, {12V and
{15VDC.
The -40] to +55] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments,
distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer
peripheral systems and industrial robot systems.
The modules have a maximum power rating of 6W and a typical full-load efficiency of 80%, continuous short circuit, EN55022 Class A conducted
noise compliance minimize design-in time, cost and eliminate the need for external filtering. Conducted and radiated emissions < A with external
coupling capacitor Cio=1 nF < B.
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
12VDC Input Models
24VDC Input Models
48VDC Input Models
Min.
-0.7
-0.7
-0.7
---
---
Max.
25
50
100
260
2,500
Unit
VDC
VDC
VDC
]
mW
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
Min.
-40
-40
-40
---
Max.
+55
+95
+125
95
Unit
]
]
]
%
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Free-Air Convection
EN55022 Class A
1
MINMAX
REV:5 2009/02/02