MIR500 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Reflected
Ripple
Current
mA (Typ.)
Efficiency
VDC
MIR501
MIR502
MIR503
MIR504
MIR505
MIR506
MIR511
MIR512
MIR513
MIR514
MIR515
MIR516
MIR521
MIR522
MIR523
MIR524
MIR525
MIR526
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
5
12
15
{5
{12
{15
5
12
15
{5
{12
{15
5
12
15
{5
{12
{15
Max.
mA
400
165
133
{100
{83
{66
400
165
133
{100
{83
{66
400
165
133
{100
{83
{66
Min.
mA
0
0
0
@Max. Load
mA (Typ.)
645
629
623
476
699
695
269
262
260
185
281
280
134
131
130
93
143
142
@No Load
mA (Typ.)
100
15
50
8
30
3
@Max. Load
% (Typ.)
62
63
64
42
57
57
62
63
64
45
59
59
62
63
64
45
58
58
Absolute Maximum Ratings
Parameter
Input Surge Voltage
( 1000 mS )
5VDC Input Models
12VDC Input Models
24VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
---
---
Max.
7.5
15
30
260
2,000
Unit
VDC
VDC
VDC
]
mW
Notes :
1. Specifications typical at Ta=+25], resistive
load, nominal input voltage, rated output
current unless otherwise noted.
2. Transient recovery time is measured to within
1% error band for a step change in output load
of 50% to 100%.
3. Ripple & Noise measurement bandwidth is
0-20 MHz.
4. All DC/DC converters should be externally
fused at the front end for protection.
Exceeding the absolute maximum ratings of the unit could cause damage. These
are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conditions
Ambient
Case
Min.
Max.
-25
+60
-25
+90
-40
+125
---
95
Free-Air Convection
EN55022 Class A
Unit
]
]
]
%
5. Other input and output voltage may be
available, please contact factory.
6. Specifications subject to change without notice.