欢迎访问ic37.com |
会员登录 免费注册
发布采购

MKW2626 参数 Datasheet PDF下载

MKW2626图片预览
型号: MKW2626
PDF下载: 下载PDF文件 查看货源
内容描述: 15W ,超宽输入范围,单和双输出DC / DC转换器 [15W, Ultra-Wide Input Range, Single & Dual Output DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 8 页 / 240 K
品牌: MINMAX [ MINMAX TECHNOLOGY CO., LTD. ]
 浏览型号MKW2626的Datasheet PDF文件第1页浏览型号MKW2626的Datasheet PDF文件第3页浏览型号MKW2626的Datasheet PDF文件第4页浏览型号MKW2626的Datasheet PDF文件第5页浏览型号MKW2626的Datasheet PDF文件第6页浏览型号MKW2626的Datasheet PDF文件第7页浏览型号MKW2626的Datasheet PDF文件第8页  
MKW2600 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Reflected
Ripple
Current
mA (Typ.)
Efficiency
VDC
MKW2621
MKW2622
MKW2623
MKW2624
MKW2625
MKW2626
MKW2627
MKW2629
MKW2631
MKW2632
MKW2633
MKW2634
MKW2635
MKW2636
MKW2637
MKW2639
24
( 9 ~ 36 )
48
( 18 ~ 75 )
VDC
3.3
5
12
15
{5
{12
{15
5.1
3.3
5
12
15
{5
{12
{15
5.1
Max.
mA
3000
3000
1250
1000
1500
{625
{500
3000
3000
3000
1250
1000
1500
{625
{500
3000
Min.
mA
300
300
125
100
150
{62.5
{50
300
300
300
125
100
150
{62.5
{50
300
@Max. Load @No Load
mA (Typ.) mA (Typ.)
528
762
735
726
25
771
735
726
787
264
381
368
363
15
386
368
363
393
40
30
@Max. Load
% (Typ.)
78
82
85
86
81
85
86
81
78
82
85
86
81
85
86
81
Absolute Maximum Ratings
Parameter
24VDC Input Models
Input Surge Voltage
( 1000 mS )
48VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
---
---
Max.
50
100
260
5,000
Unit
VDC
VDC
]
mW
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 75%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum output
loading to maintain specified regulation.
5. Operation under no-load conditions will not damage
these modules; however, they may not meet all
specifications listed.
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
RFI
Conducted EMI
Conditions
Ambient
Case
Min.
Max.
-40
+60
-40
+100
-50
+125
---
95
Free-Air Convection
Six-Sided Shielded, Metal Case
EN55022 Class A
Unit
]
]
]
%
6. All DC/DC converters should be externally fused at
the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. To order the converter with Remote On/Off function,
please add a suffix -RC (e.g. MKW2621-RC).
9. To order the converter with EN55022 Class A
function, please add a suffix A (e.g. MKW2621A).
10. Specifications subject to change without notice.
REV:0 2005/04
MINMAX
2