MPW2100 Series
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Over Line, Load & Temp.
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=50% to 100%
Conditions
Min.
---
---
---
---
---
---
---
120
---
---
---
Continuous
Typ.
{0.5
{0.5
{0.2
{0.3
55
---
---
---
150
{2
{0.01
Max.
{1.0
{2.0
{0.5
{1.0
80
100
10
220
300
{4
{0.02
Unit
%
%
%
%
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
Min.
1500
1650
1000
---
290
1000
Typ.
---
---
---
1200
330
---
Max.
---
---
---
1500
360
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Remote On/Off Control
Parameter
Supply On
Supply Off
Device Standby Input Current
Control Input Current ( on )
Control Input Current ( off )
Control Common
Vin -RC = 5.0V
Vin -RC = 0V
Conditions
Min.
2.5 to 50VDC or Open Circuit
-1
---
---
---
---
2
---
---
1
5
5
-100
Typ.
Max.
Unit
VDC
VDC
mA
uA
uA
Referenced to Negative Input
Output Voltage Trim
Parameter
Trim Up / Down Range
Conditions
% of nominal output voltage
Min.
{9.0
Typ.
{10.0
Max.
{11.0
Unit
%
Notes1:
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection.
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice.