MSKW2000 Series
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Conditions
Min.
---
Typ.
{0.5
{0.5
{0.1
{0.3
50
Max.
{1.0
{2.0
{0.3
{1.0
85
Unit
%
Dual Output, Balance Loads
Vin=Min. to Max.
---
%
---
%
Load Regulation
Io=20% to 100%
---
%
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
---
mV P-P
mV P-P
mV rms.
%
Over Line, Load & Temp
25% Load Step Change
---
---
---
140
100
---
15
115
165
---
250
500
uS
---
{2
{6
%
---
{0.01
{0.02
%/]
Continuous
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
Conditions
60 Seconds
Min.
1500
1650
1000
---
200
Typ.
---
---
---
650
Max.
---
---
---
750
Unit
VDC
VDC
M[
Flash Tested for 1 Second
500VDC
100KHz,1V
pF
260
350
KHz
MIL-HDBK-217F @ 25], Ground Benign
IPC/JEDEC J-STD-20
1000
---
---
K Hours
Moisture Sensitivity Level (MSL)
TEMPERATURE
LEVEL 2
Remote On/Off Control
Parameter
Conditions
Min.
Typ.
Max.
Unit
Supply On
2.5 to 5.5 VDC or Open Circuit
Supply off
-0.7
---
---
---
---
0.8
10
VDC
mA
uA
Device Standby Input Current
Control Input Current ( on )
Control Input Current ( off )
Control Common
---
---
---
Vin=Min. to Max.
Vin=Min. to Max.
-200
-300
uA
Referenced to Negative Input
Notes:
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2.Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice.
9. It is not recommended to use water-washing processon SMT units.
REV:5 2008/10
MINMAX
3