MSKW3000 Series
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Power Protection
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
25% Load Step Change
Over Line, Load & Temp.
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=10% to 100%
Conditions
Min.
---
---
---
---
---
---
---
115
---
---
---
Continuous
Typ.
{0.5
{0.5
{0.2
{0.3
50
---
---
---
250
{2
{0.01
Max.
{2.0
{3.0
{1.0
{1.0
85
100
15
---
500
{6
{0.02
Unit
%
%
%
%
mV P-P
mV P-P
mV rms
%
uS
%
%/]
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
MIL-HDBK-217F @ 25], Ground Benign
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
Min.
1500
1650
1000
---
---
1000
Typ.
---
---
---
650
340
---
Max.
---
---
---
750
---
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Remote On/Off Control
Parameter
Supply On
Supply off
Device Standby Input Current
Control Input Current ( on )
Control Input Current ( off )
Control Common
Vin=Min. to Max.
Vin=Min. to Max.
Conditions
Min.
-0.7
---
---
---
Typ.
---
---
---
---
Max.
0.8
10
-600
-700
Unit
VDC
mA
uA
uA
2.5 to 5.5 VDC or Open Circuit
Referenced to Negative Input
Notes:
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2.Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice.
9. It is not recommended to use water-washing process on SMT units.
3
MINMAX
REV:3 2008/10