MSLU100 Series
Output Specifications
Parameter
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Output Short Circuit
Over Line, Load & Temp.
Conditions
Dual Output , Balanced Loads
For Vin Change of 10%
Io=20% to 100%
Min.
---
---
---
---
---
---
0.5 Second Max.
Typ.
{0.1
{1.2
60
---
---
{0.01
Max.
{1.0
{1.5
120
150
15
{0.02
Unit
%
%
%
mV P-P
mV P-P
mV rms
%/]
See Model Selection Guide
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
Moisture Sensitivity Level (MSL)
TEMPERATURE
MIL-HDBK-217F @ 25], Ground Benign
IPC/JEDEC J-STD-20
Conditions
60 Seconds
Flash Tested for 1 Second
500VDC
100KHz,1V
Min.
1500
1650
1000
---
50
2000
Typ.
---
---
---
40
100
---
LEVEL 2
Max.
---
---
---
100
140
---
Unit
VDC
VDC
M[
pF
KHz
K Hours
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Ripple & Noise measurement bandwidth is 0-20 MHz.
3. These power converters require a minimum output loading to maintain specified regulation.
4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
5 All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltage may be available, please contact factory.
7. Specifications subject to change without notice.
8. It is not recommended to use water-washing process on SMT units.
Block Diagram
+Vo
+Vin
Bipolar
Push-Pull
Inverter
-Vin
-Vo
-Vin
+Vin
Bipolar
Push-Pull
Inverter
+Vo
Com.
-Vo
3