欢迎访问ic37.com |
会员登录 免费注册
发布采购

MSLU302 参数 Datasheet PDF下载

MSLU302图片预览
型号: MSLU302
PDF下载: 下载PDF文件 查看货源
内容描述: 1W ,高隔离贴片,单和双输出DC / DC转换器 [1W, High Isolation SMD, Single & Dual Output DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 6 页 / 178 K
品牌: MINMAX [ MINMAX TECHNOLOGY CO., LTD. ]
 浏览型号MSLU302的Datasheet PDF文件第1页浏览型号MSLU302的Datasheet PDF文件第2页浏览型号MSLU302的Datasheet PDF文件第3页浏览型号MSLU302的Datasheet PDF文件第4页浏览型号MSLU302的Datasheet PDF文件第6页  
MSLU300 Series
Test Configurations
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor.
Scope measurement should be made by using a BNC
socket, measurement bandwidth is 0-20 MHz. Position the
load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
To Oscilloscope
Single Output
DC / DC
+
Converter
+ Lin
-Vin
Battery
-Out
Cin
Copper Strip
+Out
Resistive
Cout
Scope
Load
DC / DC
Current
Load
Converter
Probe
Copper Strip
-Vin
-Out
+Vin
+
DC Power
Source
-
-Vin
+Vin
Single Output
DC / DC
Converter
-Out
+Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as
practicable across the load will give the best ripple and noise
performance.
To reduce output ripple, it is recommended to use 1.0uF
capacitors at the output.
Cout
Load
+Vin
Dual Output
DC / DC
Converter
-Vin
+Out
Com.
-Out
Copper Strip
Cout
Copper Strip
Cout
Copper Strip
Scope
Scope
Resistive
Load
+
DC Power
Source
-
-Vin
+Vin
+Out
Dual Output
Com.
DC / DC
Converter
-Out
Cout
Load
Design & Feature Considerations
Maximum Capacitive Load
The MSLU300 series has limitation of maximum connected
capacitance at the output.
The power module may be operated in current limiting
mode during start-up, affecting the ramp-up and the startup
time.
The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the
power module, such as orientation, airflow over the module
and board spacing. To avoid exceeding the maximum
temperature rating of the components inside the power
module, the case temperature must be kept below 90° C.
The derating curves are determined from measurements
obtained in an experimental apparatus.
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
In applications where power is supplied over long lines and
output loading is high, it may be necessary to use a capacitor
at the input to ensure startup.
Capacitor mounted close to the power module helps
ensure stability of the unit, it is recommended to use a good
quality low Equivalent Series Resistance (ESR < 1.0[ at 100
KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for
the 12V input devices and a 0.47uF for the 24V devices.
+
DC Power
Source
-
+
Cin
-Vin
-Out
+Vin
DC / DC
Converter
+Out
Load
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
5
MINMAX