MSLU300 Series  
Test Configurations  
Output Ripple Reduction  
Peak-to-Peak Output Noise Measurement Test  
A good quality low ESR capacitor placed as close as  
practicable across the load will give the best ripple and noise  
performance.  
To reduce output ripple, it is recommended to use 1.0uF  
capacitors at the output.  
Use a Cout 0.33uF ceramic capacitor.  
Scope measurement should be made by using a BNC  
socket, measurement bandwidth is 0-20 MHz. Position the  
load between 50 mm and 75 mm from the DC/DC Converter.  
+Vin  
+Out  
Copper Strip  
+
+Vin  
-Vin  
+Vin  
-Vin  
+Out  
-Out  
Scope  
Single Output  
Resistive  
Load  
DC / DC  
Cout  
Single Output  
DC / DC  
DC Power  
Source  
-Out  
Converter  
Converter  
Cout  
Load  
-Vin  
Copper Strip  
-
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
+
+Out  
Com.  
-Out  
Dual Output  
DC / DC  
Resistive  
Load  
Copper Strip  
Cout  
Dual Output  
DC / DC  
Converter  
Cout  
Load  
DC Power  
Source  
Scope  
Converter  
-Vin  
Copper Strip  
-
Design & Feature Considerations  
Maximum Capacitive Load  
The MSLU300 series has limitation of maximum connected  
capacitance at the output.  
Thermal Considerations  
The power module may be operated in current limiting  
mode during start-up, affecting the ramp-up and the startup  
time.  
Many conditions affect the thermal performance of the  
power module, such as orientation, airflow over the module  
and board spacing. To avoid exceeding the maximum  
temperature rating of the components inside the power  
module, the case temperature must be kept below 90°C.  
The derating curves are determined from measurements  
obtained in an experimental apparatus.  
The maximum capacitance can be found in the data sheet.  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power module.  
Position of air velocity  
Air Flow  
50mm / 2in  
In applications where power is supplied over long lines and  
output loading is high, it may be necessary to use a capacitor  
at the input to ensure startup.  
probe and thermocouple  
15mm / 0.6in  
DUT  
Capacitor mounted close to the power module helps  
ensure stability of the unit, it is recommended to use a good  
quality low Equivalent Series Resistance (ESR < 1.0[ at 100  
KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for  
the 12V input devices and a 0.47uF for the 24V devices.  
+
+Vin  
DC / DC  
+Out  
+
DC Power  
Source  
Load  
Converter  
Cin  
-
-Vin  
-Out  
REV:5 2009/01/20  