MITSUBISHI <INTELLIGENT POWER MODULES>
PM600DVA060
FLAT-BASE TYPE
INSULATED PACKAGE
TOTAL SYSTEM
Parameter
Supply Voltage Protected by
V
CC(PROT)
SC
Symbol
V
CC(surge)
Supply Voltage (Surge)
T
C
T
stg
V
iso
Module Case Operating
Temperature
Storage Temperature
Isolation Voltage
Condition
V
D
= 13.5 ~ 16.5V, Inverter Part,
T
j
= 125°C Start
Applied between : C
1
-E
2
, Surge value or without
switching
(Note-1)
60Hz, Sinusoidal, Charged part to Base, AC 1 min.
Ratings
400
500
–20 ~ +100
–40 ~ +125
2500
Unit
V
V
°C
°C
V
rms
(Note-1) T
C
measurement point is below. (3mm depth at the center of the side of base plate)
Tc
ELECTRICAL CHARACTERISTICS
(Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
V
CE(sat)
V
EC
t
on
t
rr
t
c(on)
t
off
t
c(off)
I
CES
Parameter
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Test Condition
V
D
= 15V, I
C
= 600A
V
CIN
= 0V
–I
C
= 600A, V
D
= 15V, V
CIN
= 5V
V
D
= 15V, V
CIN
= 0V↔5V
V
CC
= 300V, I
C
= 600A
T
j
= 125°C
Inductive Load (upper and lower arm)
V
CE
= V
CES
, V
CIN
= 5V
T
j
= 25°C
T
j
= 125°C
T
j
= 25°C
T
j
= 125°C
Min.
—
—
—
0.4
—
—
—
—
—
—
Limits
Typ.
2.35
2.55
2.20
0.8
0.2
0.3
1.8
0.6
—
—
Max.
2.80
3.05
3.30
2.1
0.3
1.1
2.9
1.2
1
10
Unit
V
V
Switching Time
µs
Collector-Emitter
Cutoff Current
mA
CONTROL PART
Symbol
I
D
V
th(ON)
V
th(OFF)
SC
t
off(SC)
OT
OT
r
UV
UV
r
I
FO(H)
I
FO(L)
t
FO
V
SXR
Parameter
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
Short Circuit Trip Level
Short Circuit Current Delay
Time
Over Temperature Protection
(Lower-arms only)
Supply Circuit Under-Voltage
Protection
Fault Output Current
Minimum Fault Output Pulse
Width
SXR Terminal Output Voltage
V
D
= 15V, V
CIN
= 5V
Applied between : C
PI
-V
PC
, C
NI
-V
NC
–20≤ T
j
≤
125°C, V
D
= 15V
V
D
= 15V
Base-plate
Temperature detection, VD = 15V
–20
≤
T
j
≤
125°C
V
D
= 15V, V
FO
= 15V
V
D
= 15V
–20
≤
T
j
≤
125°C, Rin=6.8kΩ
Trip level
Reset level
Trip level
Reset level
(Note-2)
(Note-2)
Test Condition
V
N1
-V
NC
V
P1
-V
PC
Min.
—
—
1.2
1.7
740
—
111
—
11.5
—
—
—
1.0
4.5
Limits
Typ.
27
27
1.5
2.0
—
10
118
100
12.0
12.5
—
10
1.8
5.1
Max.
38
38
1.8
2.3
—
—
125
—
12.5
—
0.01
15
—
5.6
Unit
mA
V
A
µs
°C
V
mA
ms
V
(Note-2) Fault output is given only when the internal SC, OT & UV protection.
Fault output of OT protection operate by lower arm
Fault output of OT, UV protection given pulse while over level.
Jun. 2005