MITSUMI
No-adjustment Sync Separator MM1068
Electrical Characteristics
Item
Operating power supply voltage
Consumption current
Free-running frequency NTSC
Horizontal sync signal
acquisition range NTSC
Free-running frequency PAL
Horizontal sync signal
acquisition range PAL
LPF pin DC level
Sync separation level
H. sync pulse width
H. sync delay time
H. sync output voltage L
H. sync output voltage H
V. sync pulse width
V. sync delay time
V. sync output voltage L
V. sync output voltage H
V. sync switching voltage L
(Except where noted otherwise, Ta=25°C, V
CC
=5.0V, X=CSB503F2,
R=390 [OHM], C=3300pF, SW1=ON, SW2=OFF)
Measurement
circuit
V
CC
Id
TP1
TP1
TP1
TP1
TP4
V
IN
TP1
TP1
TP1
TP1
TP3
TP3
TP3
TP3
TP2
TP2
V
IN
: signal 1
Measurement conditions
Min. Typ. Max. Units
4.7
5.0
8.0
5.3
V
Symbol
V
CC
Id
f
O
1
f
CAP
1
f
O
2
f
CAP
2
V
LPF
V
SEPA
t
W
1
T
d
1
V
L
1
V
H
1
t
W
3
t
d
3
V
L
3
V
H
3
V
THL
3
11.5 mA
15.534 15.734 15.934 kHz
*
1
*
2
300
500
Hz
X=CSB500F40, R=200OHM,
C=4700pF
X=CSB500F40, R=200OHM,
C=4700pF, V
IN
: signal 1
SW2 : ON
SW1 : OFF, V
IN
: staircase wave 1V
P-P
V
IN
: signal 1, 15.734kHz
IN
IN
IN
15.425 15.625 15.825 kHz
300
0.9
500
1.4
50
4.2
1.2
0.2
4.8
150
8.0
4.8
1.5
2.3
5.0
190
0.2
5.0
1.8
2.6
2.1
2.9
230
0.4
10.0 12.0
1.9
80
4.5
1.7
0.4
Hz
V
mV
uS
uS
V
V
uS
uS
V
V
V
V
* *
1
3
*
4
20
3.9
0.7
V. sync switching voltage H
V
THH
3
*
5
V : signal 1, 15.734kHz
*
5
V : signal 1, 15.734kHz
*
5
V : signal 1, 15.734kHz
*
5
V : staircase wave 1V
*
6
V : staircase wave 1V
*
6
V : staircase wave 1V
*
6
V : staircase wave 1V
*
6
TP2 : DC voltage 5V Low
*
7
TP2 : DC voltage 0V High
*
7
IN
IN
IN
IN
P-P
P-P
P-P
P-P
Notes:
1 Signal 1 : Pulse signal with 0.3V amplitude and pulse width 4.7µS
*
Signal 1 waveform
4.7uS
Measuring horizontal sync signal pull-in
NTSC
*
2 With TP1 waveform not synchronized to range for adjust signal 1 frequency toward 15.734kHz.
signal 1,
The
measurement value is the smaller of the synchronized frequency and the difference from 15.734.
*
3 Measuring horizontal sync signal pull-in range for PAL
*
4 Measuring sync separation level
With TP1 waveform not synchronized to signal 1, adjust signal 1 frequency toward 15.625kHz. The
measurement value is the smaller of the synchronized frequency and the difference from 15.625.
Gradually lower staircase wave signal sync tip level, and measure sync tip level when Pin 9 waveform
starts to change.