V436632Z24VXTG-75PC 参数 Datasheet PDF下载

V436632Z24VXTG-75PC图片预览
型号: V436632Z24VXTG-75PC
PDF下载: 下载PDF文件 查看货源
内容描述: 3.3伏32M ×64的高性能133 MHz的SDRAM SODIMM UNBUFFERED [3.3 VOLT 32M x 64 HIGH PERFORMANCE 133 MHZ SDRAM UNBUFFERED SODIMM]
分类和应用: 动态存储器
文件页数/大小: 12 页 / 275 K
品牌: MOSEL [ MOSEL VITELIC, CORP ]
 浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第4页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第5页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第6页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第7页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第8页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第10页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第11页浏览型号V436632Z24VXTG-75PC的Datasheet PDF文件第12页  
V436632Z24V
CILETIV LESO M
Notes:
1. The specified values are valid when addresses are changed no more than once during t
CK
(min.) and when No
Operation commands are registered on every rising clock edge during t
RC
(min). Values are shown per module
bank.
2. The specified values are valid when data inputs (DQ’s) are stable during t
RC
(min.).
3. All AC characteristics are shown for device level.
An initial pause of 100
µs
is required after power-up, then a Precharge All Banks command must be given followed
by 8 Auto Refresh (CBR) cycles before the Mode Register Set Operation can begin.
4. AC timing tests have V
IL
= 0.4V and V
IH
= 2.4V with the timing referenced to the 1.4V crossover point. The transition
time is measured between V
IH
and V
IL
. All AC measurements assume t
T
= 1 ns with the AC output load circuit
shown. Specific tac and toh parameters are measured with a 50 pF only, without any resistive termination and with
a input signal of 1V / ns edge rate between 0.8V and 2.0V.
tCH
2.4V
CLOCK
0.4V
+ 1.4 V
50 Ohm
Z=50 Ohm
I/O
50 pF
tCL
tSETUP
tHOLD
t
T
INPUT
1.4V
tAC
tLZ
tOH
tAC
I/O
50 pF
1.4V
OUTPUT
Measurement conditions for
tac and toh
tHZ
5. If clock rising time is longer than 1 ns, a time (t
T
/2 -0.5) ns has to be added to this parameter.
6. Rated at 1.5V
7. If t
T
is longer than 1 ns, a time (t
T
-1) ns has to be added to this parameter.
8. Any time that the refresh Period has been exceeded, a minimum of two Auto (CBR) Refresh commands must be
given to “wake-up” the device.
9. Self Refresh Exit is a synchronous operation and begins on the 2nd positive clock edge after CKE returns high.
Self Refresh Exit is not complete until a time period equal to t
RC
is satisfied once the Self Refresh Exit command
is registered.
10.
11.
Referenced to the time which the output achieves the open circuit condition, not to output voltage levels.
t
DAL
is equivalent to t
DPL
+ t
RP
.
V436632Z24V Rev. 1.1 February 2002
9