ACP100E
Series
Low Cost, 1W
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
Miniature Low Profile Case
•
DCP01 Series Replacement
•
1,500 VDC Isolation
•
Short Circuit Protected
•
>3.5 MHour MTBF
•
SMT Ver Available (LCP100E)
•
LOW, LOW COST!!
Input
Parameter
Input Voltage Range
Input Filter
Conditions
5 VDC Input
12 VDC Input
Min.
4.50
10.80
Typ.
5.0
12.0
Max.
5.50
13.20
Units
VDC
Internal Capacitor
Conditions
For Vin Change of 1%
See Model Selection Guide
50% Iout
100% Iout
20
50
75
±0.03
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
25
100
Conditions
Ambient
Case
-55
Free Air Convection
RH, Non-condensing
95
%
Min.
-40
Typ.
+25
Max.
+85
+100
+125
Typ.
Max.
Units
VDC
M
pF
kHz
Units
°C
°C
°C
mV P - P
%/°C
Min.
Typ.
±3.0
±1.2
Max.
Units
%
%
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz), See Note 3
Temperature Coefficient
Output Short Circuit, See Note 4
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
0.77 x 0.30 x 0.18 Inches (19.5 x 7.62 x 4.5 mm)
Non-Conductive Black Plastic (UL-94V0)
0.05 Oz (1.4g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
3.5
Typ.
Max.
Units
MHours
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Reliability Specifications
Parameter
MTBF
Shock & Vibration, See Note 5
Meets MIL-STD-202F, IEC68-2-6
Conditions
5 VDC Input
12 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
9.0
18.0
300
Units
VDC
°C
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com