C4000ERW
Series
Compact, 2:1 Input
40W, Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
40W Output Power
•
2:1 Input Voltage Range
•
1,500 VDC Isolation
•
Compact 2 x 2 In. Case
•
-40ºC to +60ºC Operation
•
>1.0 MHour MTBF
•
Remote ON/OFF
•
Industry Standard Pin-Out
Input
Parameter
Input Voltage Range
Under Voltage Shutdown
Input Filter
Start Up Time
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
8.0
24 VDC Input 16.0
48 VDC Input 33.0
(Pi) Filter
See Note 1
Conditions
For Vin Min to Max
Iout = 10% to 100%
120
110
25% Load Step Change
Min.
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
9.0
17.8
36.0
2.0
Units
VDC
VDC
A
Units
%
%
%
mV P - P
%
% Vout
µSec
%
%/°C
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Over Voltage Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Typ.
±1.0
±0.2
±0.5
75
Max.
200
150
150
130
500
±5.0
±0.02
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Case Temperature
Conditions
Min.
3.5
-0.0
Min.
1,500
1,000
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Over Temperature Protection
Remote On/Off
(Note 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Units
VDC
M
pF
kHz
°C
2,000
300
115
Typ.
Max.
Units
12.0
VDC
1.2
VDC
1
mA
Referenced to Negative Input (pin 2)
Max.
+60
+125
95
Units
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
-55
Free Air Convection
RH, Non-condensing
Ambient
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
2.0 x 2.0 x 0.42 Inches (50.8 x 50.8 x 10.6 mm)
Metal with Non-Conductive Base
2.19 Oz (60g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
1,000
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Units
kHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
20.0
40.0
80.0
300
Caution:
Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com