Model Selection Guide
Input
Model
Number
C6001RU
C6002RU
C6003RU
C6004RU
C6011RU
C6012RU
C6013RU
C6014RU
Voltage
(VDC)
Nom.
24
24
24
24
48
48
48
48
Range
9 - 36
9 - 36
9 - 36
9 - 36
18 - 75
18 - 75
18 - 75
18 - 75
Current
(mA)
Full-Load
2,437
3,086
2,976
2,941
1,188
1,506
1,488
1,453
No-Load
70
80
100
90
10
10
10
10
Voltage
(VDC)
www.micropowerdirect.com
Output
Current
(A, Max)
Current
(A, Min
Efficiency
(Typ %)
Over
Capacitive
Voltage
Load
Protection
(µF Max)
(VDC)
Fuse Rating
Slow-Blow
(mA)
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
14.00
12.00
5.00
4.00
14.00
12.00
5.00
4.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
83
85
88
89
85
87
88
90
3.9
6.2
15
18
3.9
6.2
15
18
47,000
36,000
4,700
2,200
47,000
36,000
4,700
2,200
7,500
7,500
7,500
7,500
5,000
5,000
5,000
5,000
For heatsink option, add suffix “H” to model number (i.e.
C6003RU-H)
Notes:
1. For 3.3 VDC output models, the maximum load regulation is
±0.8%.
2. When measuring output ripple, it is recommended that external 1.0 µF & 10 µF capacitors be placed in parallel
from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%.
4. If the on/off pin is left open, the unit operates. If grounded, the unit will shut off.
5. Sense pins should be connected to the output load or to the corresponding output pin.
6. No load operation will not damage these units, but they may not meet all spec’s.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the
correct rating.
External Trim
A simple external circuit may be used
to adjust the converter output. To adjust
the output DOWN, connect a 5%, 3W
resistor between the plus output pin
and the Vout trim pin. To adjust the
output UP, connect a 5%, 3W resistor
between the minus output pin and the
Vout trim pin.
For UP/Down trimming capability, con-
nect a 10 kW potentiometer between
the plus and minus outputs with the
wiper arm connected to the Vout
trim pin.
The range for the external trim is
about
±10%.
Derating Curve
(3.3VDC, 5 VDC & 12 VDC Models)
Mechanical Dimensions
Derating Curve
(15 VDC Models)
Pin Connections
Pin
1
2
3
4
Function
+V
IN
-V
IN
On/Off
-Sense
Pin
5
6
7
8
Function
+Sense
+V
OUT
-V
OUT
Trim
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
Mechanical Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
TEL: (781) 344-8226
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com