D100R
Series
Tightly Regulated
Miniature, 1W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
Tight Line/Load Regulation
•
Miniature SIP Case
•
1,000 VDC Isolation
•
>2 MHour MTBF
•
20 Standard Models
•
Industry Standard Pin-Out
Input
Parameter
Conditions
5 VDC Input
Input Voltage Range
12 VDC Input
24 VDC Input
48 VDC Input
Input Filter
Reverse Polarity Input Current
Min.
4.5
10.8
21.6
44.0
Typ.
5.0
12.0
24.0
48.0
Max.
5.5
13.2
26.4
52.0
0.3
Conditions
For Vin Min to Max
50
120
±0.01
Momentary (0.5 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
60
60
Conditions
Ambient
Case
Min.
-40
-40
-40
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+100
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
ºC
±0.02
Min.
Typ.
Max.
±2.0
±0.5
±0.5
75
A
Units
%
%
%
mV P - P
%
%/ºC
VDC
Units
Internal Capacitor
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
RoHS Compliant
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Case Size
Case Material
Weight
0.76 x 0.28 x 0.39 Inches (19.5 x 7.2 x 10.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
5 VDC Input
Input Voltage Surge (1 Sec)
12 VDC Input
24 VDC Input
48 VDC Input
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
Min.
2.0
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
55.0
260
450
ºC
mW
VDC
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.