D200ERU
Series
Low Cost, 4:1 Input
Miniature, 2W SIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
2W Output Power
•
4:1 Input Voltage Range
•
1,500 VDC Isolation
•
Short Circuit Protected
•
Miniature SIP Case
•
Single & Dual Outputs
•
1.0 MH MTBF
•
Industry Standard Pin-Out
•
Low Low Cost!!
Input
Parameter
Input Voltage Range
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
24 VDC Input
48 VDC Input
Min.
9.0
18.0
Typ.
24.0
48.0
Max.
36.0
72.0
1.0
1,500
Conditions
Min.
Typ.
±1.0
±1.0
Vin = Min to Max
Iout = 10% to 100%
See Note 1
120
±0.03
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Iout = 100%
Iout = 100%
Conditions
Ambient
100
200
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Min.
1,500
1,000
65
650
400
Max.
+85
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
kHz
Units
°C
°C
±0.2
±0.5
15
50
Max.
±3.0
±2.0
±0.75
±1.5
30
150
Units
VDC
A
mW
Units
%
%
%
%
mV P - P
mV P - P
%
%/°C
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
RoHS Compliant
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency , Single Output
Switching Frequency , Dual Output
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Humidity
Physical
Case Size
Case Material
Weight
1.02 x 0.37 x 0.49 Inches (26.0 x 9.50 x 12.50 mm)
Non-Conductive Black Plastic (UL94-V0)
0.24 Oz (7.0g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
1.0
Min.
-0.7
-0.7
Typ.
Max.
40.0
80.0
300
1,800
Typ.
Max.
Units
MHours
Units
VDC
°C
mW
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.