DRP-240
Series
Low Cost, Industrial
240W, DIN Rail Mount
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
New
Industrial
Supplies!!
Conditions
Min.
85
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Key Features:
Input
Parameter
Input Voltage Range
•
240W Output Power
•
DIN Rail Mountable
Input Frequency Range
•
Universal AC Input
Power Factor
•
UL 508 Approved
•
0.99 Power Factor Corr.
Inrush Current
•
24 VDC & 48 VDC Outputs
•
Cond./Rad. EMI Class B
Leakage Current
Output
•
>100 kH MTBF
Parameter
•
LOW COST!
Output Voltage Accuracy
Voltage Adjustment Range
Line Regulation
Load Regulation
Set Up Time
Rise Time
Hold Time
Ripple & Noise (Note 2)
Output Power Protection
Over Voltage Protection (Note 4)
Over Temperature Protection
Temperature Coefficient
Switching Frequency
General
Parameter
Isolation Voltage
230 VAC, Full Load
115 VAC, Full Load
230 VAC, Cold Start
115 VAC, Cold Start
240 VAC
Conditions
Note 1
24 VDC Output
48 VDC Output
Iout = 10% to 100%
At Full Load
At Full Load
At Full Load
24 VDC Output
48 VDC Output
Note 3
24 VDC Output
48 VDC Output
Note 5
0ºC to 50ºC
Fixed
Conditions
Input - Output
Input - FG (Frame Ground)
Output - FG (Frame Ground)
500 VDC
Conditions
Min.
24
48
0.96
0.99
45
27
3.5
Typ.
±1.0
Max.
28
53
±0.5
±1.0
800
40
24
80
150
150
36
60
105
A
mA
Units
%
VDC
%
%
mSec
mSec
mSec
mV Pk-Pk
%
VDC
ºC
%/ºC
kHz
Units
VAC
MΩ
105
30
54
95
100
±0.03
100
Typ.
RoHS Compliant
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Isolation Resistance (Note 6)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Physical
Case Size
Case Material
Connection
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
EMI Compliance
Harmonic Current Compliance
EMS Immunity Compliance
Min.
3,000
1,500
500
100
Max.
Min.
Typ.
Max.
Units
-10
+25
+70
ºC
-20
+85
ºC
RH, Non-condensing
20
90
%
RH, Non-condensing
10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
Ambient
4.94 x 4.93 x 3.94 Inches (125.5 x 125.5 x 100.0 mm)
Aluminum
Screw Terminal
42.8 Oz (1.2 kg)
Min.
Typ.
Max.
Units
105.5
kHours
UL 508, UL 60950, EN 60950-1
UL, cUL, TUV
Compliance to EN55011, EN55022 (CISPR22) Class B
Compliance to EN6100-3-2,-3
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign