欢迎访问ic37.com |
会员登录 免费注册
发布采购

E225I 参数 Datasheet PDF下载

E225I图片预览
型号: E225I
PDF下载: 下载PDF文件 查看货源
内容描述: 高隔离, 2W超微型, SIP DC / DC转换器 [High Isolation, 2W Ultra-Miniature, SIP DC/DC Converters]
分类和应用: 转换器模拟IC信号电路
文件页数/大小: 2 页 / 171 K
品牌: MPD [ MICROPOWER DIRECT, LLC ]
 浏览型号E225I的Datasheet PDF文件第1页  
Model Selection Guide
Model
Number
E201I
E202I
E203I
E204I
E205I
E211I
E212I
E213I
E214I
E215I
E222I
E223I
E224I
E225I
E232I
E233I
E234I
E235I
Input
Voltage (VDC)
Nominal
Range
5
4.5 - 5.5
5
5
5
5
12
12
12
12
12
24
24
24
24
48
48
48
48
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
44.0 - 52.0
44.0 - 52.0
44.0 - 52.0
44.0 - 52.0
Output
Load
Current (mA)
Voltage Current
Current Regulation
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)
372
38
3.3
400.0
40.0
12
533
500
500
500
150
200
211
199
208
107
102
104
102
53
52
53
52
38
38
38
38
30
30
30
25
25
12
12
12
12
6
6
6
6
5.0
9.0
12.0
15.0
3.3
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
400.0
222.0
167.0
133.0
400.0
400.0
222.0
167.0
133.0
400.0
222.0
167.0
133.0
400.0
222.0
167.0
133.0
40.0
22.0
16.0
13.0
40.0
40.0
22.0
16.0
13.0
40.0
22.0
16.0
13.0
40.0
22.0
16.0
13.0
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Efficiency
(%, Typ)
71
75
79
80
80
73
77
79
84
80
78
82
80
82
78
80
78
80
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
200
200
200
200
100
100
100
100
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may
not meet all specifications.
4. The 5V, 12V and 24V input units do not require external components to
operate, but the use of a low ESR capacitor (approximately 10
µF,
ESR
<1.0Ω at 100 kHz) mounted close to the converter input pins is recom-
mended.
For 48 VDC input units, an input capacitor should always be used. Depen-
dent upon the application, a value between 4.7
µF
and 47
µF
should be
sufficient.
5. Out put capacitive load capability of these units is 33
µF
max. Exceeding
this may cause start up problems.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Derating Curve
Pin Connections
Pin
1
2
3
4
Description
-Vin
+Vin
-Vout
+Vout
Mechanical Dimensions
Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
Pin 1 is marked by a “dot” or indentation
on the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
FAX: (781) 344-8481
E-Mail: sales@micropowerdirect.com