欢迎访问ic37.com |
会员登录 免费注册
发布采购

H111I 参数 Datasheet PDF下载

H111I图片预览
型号: H111I
PDF下载: 下载PDF文件 查看货源
内容描述: 超微型MINIDIP 1W ,高隔离的DC / DC转换器 [Ultra-Miniature MiniDIP 1W, High Isolation DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 2 页 / 174 K
品牌: MPD [ MICROPOWER DIRECT, LLC ]
 浏览型号H111I的Datasheet PDF文件第1页  
Model Selection Guide  
Input  
Output  
Current  
(mA, Max)  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Nominal Range  
Current (mA)  
Voltage  
(VDC)  
Current  
(mA, Min)  
Full-Load  
No-Load  
H101I  
H102I  
H103I  
H104I  
H105I  
H106I  
H111I  
H112I  
H113I  
H114I  
H115I  
H116I  
H121I  
H122I  
H123I  
H124I  
H125I  
H126I  
5
5
5
5
5
5
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
278  
267  
260  
256  
257  
257  
116  
112  
109  
107  
107  
107  
58  
25  
25  
25  
25  
25  
25  
16  
16  
16  
16  
16  
16  
8
3.3  
5.0  
9.0  
12.0  
15.0  
24.0  
3.3  
5.0  
9.0  
12.0  
15.0  
24.0  
3.3  
300.0  
200.0  
111.0  
83.3  
66.6  
41.6  
300.0  
200.0  
111.0  
83.3  
66.6  
41.6  
300.0  
200.0  
111.0  
83.3  
66.6  
41.6  
5.0  
4.0  
2.0  
2.0  
2.0  
2.0  
5.0  
4.0  
2.0  
2.0  
2.0  
2.0  
5.0  
4.0  
2.0  
2.0  
2.0  
2.0  
72  
75  
77  
78  
78  
78  
72  
75  
77  
78  
78  
78  
72  
75  
77  
78  
78  
78  
500  
500  
500  
500  
500  
500  
200  
200  
200  
200  
200  
200  
100  
100  
100  
100  
100  
100  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
56  
55  
54  
54  
8
8
8
8
5.0  
9.0  
12.0  
15.0  
24.0  
54  
8
Derating Curve  
Other outputs are available.  
Contact the factory for details at:  
sales@micropowerdirect.com  
Notes:  
1. Output load regulation is specified for a load change of  
20% to 100%.  
2. When measuring output ripple, it is recommended that  
an external 0.33 µF ceramic capacitor be placed from the  
+Vout pin to the -Vout pin.  
3. Operation at no-load will not damage these units. How-  
ever, they may not meet all specifications.  
4. The 5V, 12V and 24V input units do not require external  
components to operate, but the use of a low ESR capaci-  
tor (approximately 10 uF, ESR <1.0Ω at 100 kHz) mounted  
close to the converter input pins is recommended.  
For 48 VDC input units, an input capacitor should always be  
used. Dependent upon the application, a value between  
4.7 µF and 47 uF should be sufficient.  
5. It is recommended that a fuse be used on the input of a  
power supply for protection. See the table above for the  
correct rating.  
Mechanical Dimensions  
Capacitive  
Load  
(µF Max)  
220  
Pin Connections  
Pin  
Function  
1
4
5
7
-Vin  
+Vin  
+Vout  
-Vout  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” or indentation on the top  
of the unit  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com