LF200ED
Series
Low Cost, 2W SMT
Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
2W Output Power
•
Ultra-Miniature SMT Case
•
1,000 VDC Isolation
•
-40ºC to +85ºC Operation
•
Dual Output
•
Low 0.24” Profile
•
>3.5 MHour MTBF
•
Industry Standard Pin-Out
•
LOWEST COST!
Input
Parameter
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Capacitor
Conditions
For Vin Change of 1%
For Iout = 10% to 100%
±7
75
150
Momentary (0.5 Sec.)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
70
70
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
Min.
Typ.
±3.0
±1.2
±15
150
250
±0.03
Max.
Units
%
%
%
mV P - P
mV P - P
%/ºC
Conditions
5 VDC Input
12 VDC Input
Min.
4.5
10.8
Typ.
5.0
12.0
Max.
5.5
13.2
1.0
Units
VDC
A
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Output Ripple (20 MHz)
Output Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Case Size
Case Material
Weight
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
5 VDC Input
12 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
3.5
Min.
-0.7
-0.7
Typ.
Max.
7.0
15.0
260.0
450
Typ.
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
0.70 x 0.72 x 0.24 Inches (17.78 x 18.03 x 6.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.05 Oz (1.5g)
Max.
Units
MHours
Units
VDC
ºC
mW
T:
(781) 344-8226
Reliability Specifications
F:
(781) 344-8481
Parameter
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.