MPG-120S
Series
Single Output, 120W
Green, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
•
120W Output Power
•
150W With Only 7 CFM
•
Universal 85-264 AC Input
•
EN 60950 Approved (UL)
•
Meets ErP Directive
•
Compact 3 x 5 Inch Size
•
PFC Meets EN 61000-3
•
Optional +5V SB Output
•
>400 kHour MTBF
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Power Factor Correction
Leakage Current
No Load Power Consumption
Conditions
Min.
Typ.
Max.
Universal
85
264
110
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
30.0
Cold Start, 230 VAC
60.0
Meets EN 61000-3-2/3 Class A
0.25
0.5
Max.
Units
VAC
VDC
Hz
A Pk
mA
W
Units
%
%
%
%
mSec
%/°C
%
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
See Note 2
±1.0
See Note 3
±1.0
See Note 4
±1.0
115 VAC
20
230 VAC
40
±0.05
140
Continuous (Autorecovery)
Conditions
Input to Output
500 VDC
Min.
3,000
Typ.
100
2,200
Min.
Typ.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI Characteristics
Parameter
Radiated Emissions, See Note 5
Conducted Emissions , See Note 5
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips, See Note 6
Max.
Units
VAC
M
pF
Standard
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Switching Frequency
Max.
Units
Class B
Class B
Criteria A; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV Line & PE
Criteria A; L-N: ±1kV, L/N-PE: ±2kV
Criteria A; 10 Vrms
Criteria A; 10A/ms
Criteria A; Volt. Dips >95%, 0.5 Cycle
Criteria A; Volt. Dips 30%, 25 Cycles
EN 61000-4-11
Criteria A/B; Volt. Dips 60%, 5 Cycles
Criteria C; Volt. Inter, >95%, 250 Cycles
Fixed
65
kHz
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Units
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
Ambient
-20
+25
+70
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
5.00 x 3.00 x 1.35 Inches (127.00 x 76.20 x 34.2 mm)
9.87 Oz (0.280 kg)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
400
UL 60950, EN 60950
Max.
Units
kHours
Reliability Specifications
Parameter
MTBF
Safety Standards
www.micropowerdirect.com