欢迎访问ic37.com |
会员登录 免费注册
发布采购

MP1530DQ-LF-Z 参数 Datasheet PDF下载

MP1530DQ-LF-Z图片预览
型号: MP1530DQ-LF-Z
PDF下载: 下载PDF文件 查看货源
内容描述: [Switching Regulator, Current-mode, 3.6A, 1400kHz Switching Freq-Max, 3 X 3 MM, ROHS COMPLIANT, MO-220VEED-4, QFN-16]
分类和应用:
文件页数/大小: 5 页 / 192 K
品牌: MPS [ MONOLITHIC POWER SYSTEMS ]
 浏览型号MP1530DQ-LF-Z的Datasheet PDF文件第1页浏览型号MP1530DQ-LF-Z的Datasheet PDF文件第2页浏览型号MP1530DQ-LF-Z的Datasheet PDF文件第3页浏览型号MP1530DQ-LF-Z的Datasheet PDF文件第4页  
TM
EV0055 (MP1530) TRIPLE OUTPUT STEP-UP PLUS CHARGE PUMP FOR TFT BIAS
EVALUATION BOARD
QUICK START GUIDE
The three output voltages of this board are set to +13V, +27V, and –8.5V. The board layout
accommodates most commonly used inductors and output capacitors.
1. Attach the positive end of loads to the VMAIN, VGH and GND (for the negative output) pins,
respectively. Attach negative ends of the loads to GND and VGL (for the negative output) pins.
2. Attach an input voltage 2.7V
V
IN
5.5V and input ground to the VIN and GND pins,
respectively.
3. The demo board starts up automatically once V
IN
is applied due to the pull-up resistor R1. To
disable the MP1530 connect the EN pin to ground.
4. During startup
RDY
will be left HIGH. Once the turn-on sequence is complete, this pin will be
pulled LOW if all regulators exceed 80% of their specified voltages. After all regulators are
turned-on, a fault in any regulator will cause
RDY
to go HIGH after approximately 15µs. If the
fault persists for more than approximately 6ms (for CT=10nF), the entire chip will shut down.
5. To adjust the output voltages:
Use a 10kΩ to 50kΩ for the low-side resistor of each voltage divider (i.e. R7, R9 and R5).
V
FB1
= V
FB3
= V
REF
= 1.25V.
For the step-up converter, determine the high-side resistor R6 using the equation:
R6
=
V
MAIN
V
FB1
V
FB1
R7
Where V
MAIN
is the output voltage of the step-up converter.
For the positive charge-pump, determine the high-side resistor R8 by the equation:
R8
=
V
GH
V
FB3
V
FB3
R9
Where V
GH
is the output voltage of the positive linear regulator. Determine the number of
positive charge pump stages (N
POS
) by:
N
POS
=
V
GH
+
V
DROPOUT
V
MAIN
V
MAIN
2V
D
Use V
DROPOUT
= 1V and V
D
= 0.4V for Schottky diodes.
For the negative charge-pump, determine the high-side resistor R4 by the equation:
R4
=
V
GL
V
REF
R5
Where V
GL
is the output voltage of the negative linear regulator. Determine the number of
negative charge pump stages (N
NEG
) by:
N
NEG
=
V
GL
+
V
DROPOUT
V
MAIN
2V
D
Use V
DROPOUT
= 0.3V and V
D
= 0.4V for Schottky diodes.
NOTICE:
The information in this document is subject to change without notice. Please contact MPS for current specifications.
Users should warrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS
products into any application. MPS will not assume any legal responsibility for any said applications.
EV0055 Rev. 1.3
8/22/2005
www.MonolithicPower.com
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.
© 2005 MPS. All Rights Reserved.
5