MP6211/MP6212 –CURRENT-LIMITED POWER DISTRIBUTION SWITCHES  
DETAILED DESCRIPTION  
Over Current  
Thermal Protection  
When the load exceeds trip current (minimum  
threshold current triggering constant-current  
mode) or a short is present, MP6211/MP6212  
switches into to a constant-current mode (current  
limit value). MP6211/MP6212 will be shutdown  
only if the overcurrent condition stays long  
enough to trigger thermal protection.  
The purpose of thermal protection is to prevent  
damage in the IC by allowing exceptive current to  
flow and heating the junction. The die temp. is  
internally monitored until the thermal limit is  
reached. Once this temp. is reached, the switch  
will turn off and allow the chip to cool. The switch  
has a built-in hysteresis.  
Trigger overcurrent protection for different  
overload conditions occurring in applications:  
Under-voltage Lockout (UVLO)  
This circuit is used to monitor the input voltage to  
ensure that the MP6211/6212 is operating  
correctly. This UVLO circuit also ensures that  
there is no operation until the input voltage  
reaches the minimum spec.  
1) The output has been shorted or overloaded  
before the device is enabled or input applied.  
MP MP6211/MP6212 detects the short or  
overload and immediately switches into a  
constant-current mode.  
Enable  
2) A short or an overload occurs after the device  
is enabled. After the current-limit circuit has  
been tripped (reached the trip current  
threshold), the device switches into constant-  
current mode. However, high current may  
flow for a short period of time before the  
current-limit circuit can react.  
The logic pin disables the chip to reduce the  
supply current. The device will operate once the  
enable signal reaches the appropriate level. The  
input is compatible with both COMS and TTL.  
3) Output current has been gradually increased  
beyond the recommended operating current.  
The load current rises until the trip current  
threshold is reached or until the thermal limit  
of the device is exceeded. The MP6211/  
MP6212 is capable of delivering current up to  
the trip current threshold without damaging  
the device. Once the trip threshold has been  
reached, the device switches into its  
constant-current mode.  
Flag Response  
The FLAG pin is an open drain configuration.  
This FAULT will report a fail mode after an 8ms  
deglitch timeout. This is used to ensure that no  
false fault signals are reported. This internal  
deglitch circuit eliminates the need for extend  
components. The FLAG pin is not deglitched  
during an over temp. or a voltage lockout.  
MP6211_MP6212 Rev. 1.1  
9/18/2009  
www.MonolithicPower.com  
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.  
© 2009 MPS. All Rights Reserved.  
8