CCFL TRANSFORMER
P9101 SERIES
Industries
•
Output power up to 6 Watts
•
Designed for 40KHz - 100KHz LCD backlight applications
• Add Schematic Suffix Letter after the Part No. ( Example:
P9101-1A for Schematic A )
•
Operating Temperature: -40°C to +85°
•
RoHS compliant product
ELECTRICAL PARAMETERS @25°C
Part Number
P9101-
1
2
3
4
5
6
7
8
9
•
•
Pri
OCL
Nom
(µH)
44
44
44
44
31
40
22
20
20
DCR
Max
(Ω)
0.22
0.16
0.22
0.16
0.13
0.18
0.13
0.13
0.13
Vpri
Volt
Turns Ratio
Pri: Sec
±5%
Isec (7-10) Sec (7-10)
Max
DCR
(mA)
Max
Pri: Fb
(Ω)
±5%
1:0.19
1:0.17
1:0.14
1:0.17
1:0.21
1:0.25
1:0.25
1:0.17
1:0.25
5
11
7
11
11
11
11
11
11
285
176
165
132
176
176
176
176
291
Fb
DCR
Max
(Ω)
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
23
20
32
26
18
17
16
13
13
1:67
1:67
1:50
1:50
1:86
1:93
1:100
1:100
1:125
Inductance measured @ 100KHz, 0.1VRMS for both halves Primary ( Example: 1-3, 1-5)
Hipot: 1500VRMS, 5 seconds ( Pri and Fb to Sec ); Schematic D is 500VRMS
DIMENSIONS
SCHEMATIC A
SCHEMATIC B
SCHEMATIC C
Product performance is limited to specified parameters. Data is subject to change without prior notice.
Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.015
.XXX : ±0.004
mm: X,X : ±0,38
X,XX : ±0,10
13200 Estrella Ave., Bldg. B
Gardena, CA 90248
Tel: 310-325-1043
Fax: 310-325-1044
www.mpsind.com
sales@mpsind.com