WIDE BAND ISOLATION
TRANSFORMER
R3600 SERIES
• For RF, DS3/E3, Boradband, BPL and Ethernet Magnetics
which require Supplementary or Reinforced Isolation
•
Construction complies with IEC60950 Isolation requirement
• RoHS Compliant Product
• Operating Temp : 0°C to 70°C (extended temperature
subject to request)
ELECTRICAL SPECIFICATION @ 25°C
PART NO
Turns
Ratio
Pri : Sec ±5%
1:1
1CT:1CT
1:2
1:1:1
3:3:1
1:1.224
Pri OCL
(µH) Min
1-4
500
800
120
120
200
500
Pri DCR
(W) Max
1-4
0.30
0.50
0.20
0.20
0.30
0.50
Insertion Loss Insertion Loss Insertion Loss
dB Max
dB Max
dB Typ
1MHz
-0.5
-0.5
-0.8
-0.8
-0.5
-0.8
100MHz
-1.0
-1.2
-1.0
-1.0
-1.0
-1.0
300MHz
-2.6
-3.5
-1.5
-1.5
-3.0
-3.0
Hipot
V
RMS
Pri to Sec
4500
3000
4500
4500
3000
3000
B
A
B
C
C
B
Schematic
R3600-
1
2
3
4
5
6
Note:
• OCL measured @ 100KHz, 0.1V
RMS
at Pin 1-4 (with 2-3 shorted)
• Insertion Loss measured with 100W as Input (Primary) Impedance between 1-4 and Output (Secondary) load with respective impedance
• 50W and 75W impedance data available upon request
Mechanical
Schematic
Schematic A
Schematic B
Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ± 0.015 .XXX : ±0.004
mm: X,X : ± 0,38 X,XX : ±0,10
Schematic C
R3600-XX
1004JW
Product performance is limited to specified parameter. Data is subject to change without prior notice.
2570 W. 237th Street, Suite B
Torrance, CA 90505
Tel: (310) 325-1043
Fax: (310) 325-1044
www.mpsind.com
sales@mpsind.com