A tognum grouP BrAnd
DIESEL ENGINE-GENERATOR SET
40-JC6DT3
40 ekW
/
60 Hz
/
Standby
35 ekW
/
60 Hz
/
Prime
208 - 600V
SySTEm RATINGS
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
240V**
1
1.0
60
40
40
167
63
361CSL1601
130°C/27°C
12 LEAD ZIG-ZAG
240V**
1
1.0
60
40
40
167
99
284CSL1550
130°C/27°C
4 LEAD
208V**
3
0.8
60
40
50
139
85
284CSL1542
130°C/27°C
12 LEAD LOW WYE
240V**
3
0.8
60
40
50
120
132
284CSL1542
130°C/27°C
12 LEAD HI DELTA
480V**
3
0.8
60
40
50
60
122
284CSL1508
130°C/27°C
12 LEAD HI WYE
600V**
3
0.8
60
40
50
48
92
361PSL1632
125°C/40°C
4 LEAD WYE
Prime
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model*
Temp Rise
Connection
240V
1
1.0
60
35
35
146
102
361CSL1601
105°C/40°C
12 LEAD ZIG-ZAG
240V
1
1.0
60
35
35
146
102
284CSL1550
105°C/40°C
4 LEAD
208V
3
0.8
60
35
43.75
121
100
284CSL1542
105°C/40°C
12 LEAD LOW WYE
240V
3
0.8
60
35
43.75
105
100
284CSL1542
105°C/40°C
12 LEAD HI DELTA
480V
3
0.8
60
35
43.75
53
133
284CSL1508
105°C/40°C
12 LEAD HI WYE
600V
3
0.8
60
35
43.75
42
92
361PSL1632
105°C/40°C
4 LEAD WYE
* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered