欢迎访问ic37.com |
会员登录 免费注册
发布采购

C1U-W-1200-48-TB2C 参数 Datasheet PDF下载

C1U-W-1200-48-TB2C图片预览
型号: C1U-W-1200-48-TB2C
PDF下载: 下载PDF文件 查看货源
内容描述: AC / DC前端电源 [AC/DC Front End Power Supply]
分类和应用: 输出元件
文件页数/大小: 4 页 / 155 K
品牌: MURATA-PS [ MURATA POWER SOLUTIONS INC. ]
 浏览型号C1U-W-1200-48-TB2C的Datasheet PDF文件第2页浏览型号C1U-W-1200-48-TB2C的Datasheet PDF文件第3页浏览型号C1U-W-1200-48-TB2C的Datasheet PDF文件第4页  
http:/ www.murata-ps.com
PRODUCT OVERVIEW
C1U-W-1200-48-Tx Series
AC/DC Front End Power Supply
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power
supply for general applications. The main output is 48V and standby output of either 5V, 3.3V, or 12V.
Packaged in U low profile, it is designed to deliver reliable bulk power to servers, workstations, storage
systems or any 48V distributed power architecture systems requiring high power density. The highly
efficient electrical and thermal design with internal cooling fans supports reliable operation conditions.
The C1U-W-1200 is designed to auto-recover from over-temperature faults.
FEATURES

compliant
RoHS

1200W (110/220Vac) Output power

Main output,
48V
3.3V, 5V or 12V standby output

Dimensions: 1.67” x 5.5” x 14.2”

Watts per cubic inch density
9.2

redundancy capable,
N+1

Active current sharing on main output

Over-voltage, over-current,
over-temperature protection

Internal cooling fans
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
SELECTION GUIDE
Part Number
C1U-W-1200-48-TA1C
C1U-W-1200-48-TC1C
C1U-W-1200-48-TA2C
C1U-W-1200-48-TC2C
C1U-W-1200-48-TB1C
C1U-W-1200-48-TB2C
Power Output
Universal Line
1200W
1200W
1200W
1200W
1200W
1200W
Main Output
48V
48V
48V
48V
48V
48V
Standby
Output
5V
3.3V
5V
3.3V
12V
12V
Airflow
Front to back
Front to back
Back to front
Back to front
Front to back
Back to front
Conditions
Min.
90
47
78.5
70.5
Typ.
55
Max.
264
63
86.5
78
15
90
Units
Vac
Hz
Vac
Arms
Apk
Ramp up
Ramp down
Output load >90%
Output load >50%
95%
75%
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
Parameter
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
1
Operating Range
Load Capacitance
Conditions
Min.
46.54
Typ.
48
Max.
49.44
480
24.6
10000
Units
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
48V
20MHz Bandwidth
2
3.3
3.2
0
5
4.85
0
12
11.2
0
3.3Vsb
3.4
50
4.5
1530
5.15
50
4
1530
12.4
120
1.7
1530
5Vsb
12Vsb
 
For full details go to
www.murata-ps.com/rohs
Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of
the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used.
1
www.murata-ps.com
Technical enquiries
email: toronto@murata-ps.com, tel:
+1 (866) 740 1232
C1U-W-1200-48-Tx.A04
Page 1 of 4