欢迎访问ic37.com |
会员登录 免费注册
发布采购

DMS-30PC-2-QS-C 参数 Datasheet PDF下载

DMS-30PC-2-QS-C图片预览
型号: DMS-30PC-2-QS-C
PDF下载: 下载PDF文件 查看货源
内容描述: 3.5位, LED显示屏低功耗,微型数字式面板电压表 [3½ Digit, LED Display Low-Power, Miniature Digital Panel Voltmeters]
分类和应用:
文件页数/大小: 6 页 / 210 K
品牌: MURATA-PS [ MURATA POWER SOLUTIONS INC. ]
 浏览型号DMS-30PC-2-QS-C的Datasheet PDF文件第1页浏览型号DMS-30PC-2-QS-C的Datasheet PDF文件第3页浏览型号DMS-30PC-2-QS-C的Datasheet PDF文件第4页浏览型号DMS-30PC-2-QS-C的Datasheet PDF文件第5页浏览型号DMS-30PC-2-QS-C的Datasheet PDF文件第6页  
DMS-30PC Series
Performance/Functional Specifications
Typical at T
A
= +25°C and supply voltage = +5V using the single-ended input
circuit, unless otherwise noted.
Analog Inputs
Full Scale Input Range:
DMS-30PC-0
DMS-30PC-1
DMS-30PC-2
DMS-30PC-3
Input Impedence:
DMS-30PC-0, -1
DMS-30PC-2, -3
Overvoltage Protection
Common Mode Voltage Range
CMRR (dc to 60Hz)
Control Inputs
Decimal Point Placement
(Pins 4-6)
Display Test
(Pin 2)
Performance
Sampling Rate
Accuracy
(3 minute warm-up):
DMS-30PC-0 (Vin = +0.19V)
DMS-30PC-1 (Vin = +1.9V)
DMS-30PC-2 (Vin = +19V)
DMS-30PC-3 (Vin = +190V)
Zero Reading
(Vin = 0 Volts)
Temperature Drift (0 = +60°C)
+1.23V Reference Output
(Pin 9)
Power Supply Requirements
Supply Voltage
Supply Current:
Standard Models
Low-Power Models
Red Display
Green or Orange Display
Display
Display Type and Size
Polarity Indication
Overrange Indication
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity (non-condensing)
Case Material
Weight
0
–40
0
+60
+75
95
°C
°C
%
3�½ digit, 0.56"/14.2mm high LED
Autopolarity ("–" for negative Vin)
"–1_ _ _ " for negative inputs
"1_ _ _ " for positive inputs
+12
+60
+17
+100
mA
mA
+150
+225
mA
+4.75
+5.00
+5.25
Volts
“–001”
+1.20
±1
±1
±2
±2
“000”
±0.2
+1.23
±3
±3
±3
±3
“001”
±0.4
+1.25
Cnts/°C
Volts
Counts
Counts
Counts
Counts
Add-On Application Boards:
DMS-EB-C
Multi-purpose (gain/offset, 4-20mA, etc.)
DMS-EB-HTB
High-accuracy temperature probe sensing for
±200mV models
DMS-EB-DC/DC
Provides isolated +5V power
DMS-EB-RMS-C
For true rms measurements of ac voltages
DMS-EB-AC/DC-C
For ac line-powered applications
A panel-mount retaining clip is supplied with each model.
2.5 reading per second
Tie to pin 3 to activate
Tie to +5V to activate all segments
100
0.8
1000
1
86
±250
±2
Volts
Volts
dB
±200
±2
±20
±200
mV
Volts
Volts
Volts
Input Range:
0
= ±200mV
1
= ±2V
2
= ±20V
3
= ±200V
±200V
available on the
following models only:
-BS (Super Blue)
-GS (Standard Green)
-RS (Standard Red)
-RL (Low-Power Red)
-VFS (Blue-Green)
Accessories:
DMS-PS1-CM-C
DMS-30-CP
DMS-BZL1-C
DMS-BZL2-C
Min.
Typ.
Max.
Units
3�½ Digit, LED Display Low-Power,
Miniature Digital Panel Voltmeters
Ordering Information
DMS-30PC - 1 - R S - C
Add -C for RoHS
LED Color:
AS
= Standard Amber
BS
= Super Blue
GS
= Standard Green
OS
= Standard Orange
QS
= Standard Aqua
RS
= Standard Red
YS
= Standard Yellow
RH
= High-Intensity Red
GL
= Low-Power Green
OL
= Low-Power Orange
RL
= Low-Power Red
VFS
= Blue-Green
+5V/1.0A AC/DC power supply module
Panel cutout punch
DMS-30 bezel assembly
DMS-30 bezel assembly with sealing gasket
TECHNICAL NOTES
1. +1.23V REFERENCE OUTPUT (Pin 9):
This pin is the output
of the meter’s precision +1.23V internal reference, and it is
referenced to ANALOG COMMON (pin 10) which sits at a potential
of approximately +2V. This output should be buffered if used to
drive external loads since sourcing more than 15μA from pin 9 can
affect both the initial accuracy and temperature drift of the meter.
2. ANALOG COMMON (Pin 10):
This pin is connected to an internal,
low-noise, "relative" ground. It is used in certain differential and
"floating" measurements as described in the Applications section
of this data sheet and Ap Note 3 of the DATEL Panel Meter Catalog.
Pin 10 should not be connected to pin 3 (5V RETURN) or to your
system’s analog ground.
3. REFERENCE OUTPUT (Pin 8) and INPUT (Pin 7):
Pin 8 is a preci-
sion reference actively trimmed at the factory. In normal opera-
tion, pin 8 must be tied to pin 7 to achieve all listed accuracy and
drift specifications.
Polycarbonate
0.75 ounces (21 grams)
Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11) with
(–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected
(see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.
See Technical Notes.
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MPM_DMS_30PC.F03
Page 2 of 6