www.murata-ps.com
PRODUCT OVERVIEW
The OKL-T/3 series are miniature non-isolated
Point-of-Load (PoL) DC/DC power converters for
embedded applications. Featuring
iLGA
inspectable
Land Grid Array (LGA) format, the OKL measures
only 0.48 x 0.48 x 0.25 inches (12.2 x 12.2 x 6.35
mm).
The wide input range is 4.5 to 14 Volts DC. The
maximum output current is 3 Amps (T/3 models).
Based on fixed-frequency synchronous buck con-
verter switching topology, the high power conver-
OKL-T/3-W12 Series
Programmable Output 3-Amp
iLGA
SMT PoLs
Typical unit
sion efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, over-
current and over temperature protections.
An optional sequence/tracking feature on OKL2
models allows power sequencing of PoL’s. These
units are designed to meet all standard UL/EN/IEC
60950-1 safety certifications and RoHS-6 hazard-
ous substance compliance.
FEATURES
■
■
■
■
■
■
■
■
■
iLGA
inspectable Land Grid Array
4.5-14Vdc input voltage range
Programmable output voltage from 0.591-5.5Vdc
Drives up to 200 μF ceramic capacitive loads
High power conversion efficiency at 93%
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control and Power Good signal
Optional Sequence/Tracking operation (OKL2
models)
Designed to meet UL/EN/IEC 60950-1 safety
(pending)
RoHS-6 hazardous substance compliance
Contents of full data sheet
Description, Connection Diagram, Photograph
Ordering Guide, Model Numbering, Product Label
Mechanical Specifications, Input/Output Pinout
Detailed Electrical Specifications
Output Voltage Adjustment, Application Notes
Soldering Guidelines
Performance Data and Oscillograms
Tape and Reel Information
Page
1
2
3
4
5
7
8
15
■
■
Connection Diagram
+Vin
F1
+Vout
On/Off
Control
Sense
Controller
External
DC
Power
Source
Trim
Open = On
Closed = Off
(Positive
On/Off)
Common
Reference and
Error Amplifier
Common
Power Good out
Figure 1. OKL-T/3
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
Sequence/Tracking
(OKL2 Models)
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_MDC_OKL-T/3-W12
Series.A05