www.murata-ps.com
PRODUCT OVERVIEW
OKX
T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Typical unit
The OKX-T/10 and -T/16 series are miniature
SIP non-isolated Point-of-Load (POL) DC/DC power
converters for embedded applications. The module
is fully compatible with Distributed-power Open
Standards Alliance (DOSA) industry-standard
specifications (www.dosapower.com). Applications
include powering CPU’s, datacom/telecom systems,
programmable logic and mixed voltage systems.
The wide input range is 2.4 to 5.5 Volts DC. Two
maximum output currents are offered, 10 Amps
(T/10 models) or 16 Amps (T/16 models). Based
on fixed-frequency synchronous buck converter
switching topology, the high power conversion
efficient Point of Load (POL) module features pro-
grammable output voltage and On/Off control. An
optional Sequence/Tracking input allows controlled
ramp-up and ramp-down outputs. The Sense input
provides load compensation. These converters also
include under voltage lock out (UVLO), output short
circuit protection, over-current and over tempera-
ture protections.
These units are designed to meet all standard
UL/EN/IEC 60950-1 safety certifications and RoHS-
6 hazardous substance compliance.
FEATURES
Non-isolated SIP POL DC/DC power module
2.4-5.5Vdc input voltage range
Programmable output voltage from 0.7525-3.63Vdc
10 Amp (T/10) or 16 Amp (T/16) output current
models
Drives 1000 μF ceramic capacitive loads
High power conversion efficiency 95% at 3.3 Vout
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control, Sense and optional Sequence/
Tracking input
UL/EN/IEC 60950-1 safety
Industry-standard (DOSA) SIP format
RoHS-6 hazardous substance compliance
Connection Diagram
+Vin
F1
+Vout
Contents of full data sheet
Page
Description, Connection Diagram, Photograph
1
Ordering Guide, Model Numbering
2
Mechanical Specifications, Input/Output Pinout
3
Detailed Electrical Specifications
5
Output Voltage Adjustment, Soldering Guidelines, Product Label 6
Application Notes
7
OKX-T/10-W5 Performance Data
10
OKX-T/16-W5 Oscillograms and Performance Data
11
On/Off
Control
Sense
Controller
External
DC
Power
Source
Trim
Open = On
Closed = Off
(Positive
On/Off)
Common
Reference and
Error Amplifier
Common
Sequence/Tracking (optional)
Figure 1. OKX2-T/10, -T/16
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
19 Oct 2009
email: sales@murata-ps.com
MDC_OKX_T10T16-W5 Series.A01_short