欢迎访问ic37.com |
会员登录 免费注册
发布采购

OKY-T/16-D12N-C 参数 Datasheet PDF下载

OKY-T/16-D12N-C图片预览
型号: OKY-T/16-D12N-C
PDF下载: 下载PDF文件 查看货源
内容描述: 可编程DOSA - SMT 10/16放大器的DC / DC转换器 [Programmable DOSA-SMT 10/16-Amp DC/DC Converters]
分类和应用: 转换器放大器
文件页数/大小: 17 页 / 641 K
品牌: MURATA-PS [ MURATA POWER SOLUTIONS INC. ]
 浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第1页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第2页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第3页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第5页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第6页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第7页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第8页浏览型号OKY-T/16-D12N-C的Datasheet PDF文件第9页  
OKY
-T/10 & T/16-D12 Series
Programmable DOSA-SMT 10/16-Amp DC/DC Converters
Performance and Functional Specifications
See Note 1
Input
Output, continued
Input Voltage Range
Start-Up Voltage
Undervoltage Shutdown (see Note 15)
Overvoltage Shutdown
Reflected (Back) Ripple Current (Note 2)
Internal Input Filter Type
Recommended External Fuse
Reverse Polarity Protection
Input Current:
Full Load Conditions
Inrush Transient
Shutdown Mode (Off, UV, OT)
Output in Short Circuit
No Load
Low Line (Vin=Vmin, Vout=Vnom)
Remote On/Off Control (Note 5)
Negative Logic (“N” model suffix)
Positive Logic (“P” model suffix)
See Ordering Guide.
8.00V
7.75V)
None
20 mA pk-pk
Capacitive
15A (T/10); 20A (T/16)
N/A. See fuse information
See Ordering Guide
0.4 A
2
Sec.
5 mA
100 mA (T/10); 60 mA (T/16)
80 mA
6.34 A (T/10);10.2 A (T/16)
ON = Open pin or ground to +0.3V. max.
OFF =+2.5V min. to + Vin (max)
ON = Open pin to +Vin max.
(internally pulled up)
OFF = Ground pin to +0.3V. max.
1 mA max.
2 Volts per millisecond, max.
Vout = +/-100 mV of Sequence In
Vout = +/-200 mV of Sequence In
Short Circuit Duration
Prebias Startup
Continuous, no damage
(output shorted to ground)
Converter will start up if the external
output voltage is less than Vset
Dynamic Load Response
75 μSec max. to within ±2% of final value
(50-100% load step, di/dt=2.5A/μSec)
Environmental
Operating Temperature Range (Ambient)
See derating curves
-40 to +85° C. with derating (Note 9)
Operating PC Board Temperature
-40 to +100° C. max.,
no derating (12)
Storage Temperature Range
-55 to +125° C.
Thermal Protection/Shutdown
+130° C.
Relative Humidity
to 85%RH/+85° C., non-condensing
Physical
Outline Dimensions
Weight
Electromagnetic Interference
Current
Tracking/Sequencing
Slew Rate
Tracking accuracy, rising input
Tracking accuracy, falling input
Restriction of Hazardous Substances
MSL Rating
See Mechanical Specifications
0.1 ounces (2.8 grams)
Designed to meet FCC part 15, class B,
EN55022 and CISPR22 class B radiated
(may need external filter)
RoHS-6 (does
not claim EU RoHS exemption
7b–lead in solder)
2
Absolute Maximum Ratings
General and Safety
Efficiency
Switching Frequency
See Ordering Guide
300 KHz ± 25 kHz
Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal
(On/Off to Vout regulated)
8 mSec for Vout=nominal
Isolation
Not isolated
Safety
Calculated MTBF
Meets UL/cUL 60950-1,
CSA-C22.2 No. 60950-1, IEC/EN 60950-1
See table on page 17.
Output
Input Voltage (Continuous or transient)
On/Off Control
Input Reverse Polarity Protection
Output Current (Note 7)
Storage Temperature
Lead Temperature
0 V.to +15 Volts max. (D12 models)
0 V. min. to +Vin max.
See Fuse section
Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
-55 to +125° C.
See soldering specifications
Output Voltage Range
Minimum Loading
Accuracy (50% load, untrimmed)
Overvoltage Protection (Note 16)
Temperature Coefficient
Ripple/Noise (20 MHz bandwidth)
Line/Load Regulation
Maximum Capacitive Loading (Note 14)
Cap-ESR=0.001 to 0.01 Ohms
Cap-ESR >0.01 Ohms
Current Limit Inception (Note 6)
(98% of Vout setting, after warm up)
Short Circuit Mode
Short Circuit Current Output
Protection Method
0.7525 to 5.5 V
No minimum load
±2 % of Vnominal
None
±0.02% per oC of Vout range
See Ordering Guide and note 8
See Ordering Guide and note 10
1,000 μF
5,000 μF
27 Amps (T/10); 33 Amps (T/16)
Absolute maximums are stress ratings. Exposure of devices to greater than any of any
of these conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifications Table is
not implied nor recommended.
Specification Notes:
(1)
Specifications are typical at +25 deg.C, Vin=nominal (+12V. for D12 models), Vout=nominal (+5V for D12
models), full load, external caps and natural convection unless otherwise indicated. Extended tests at higher
power must supply substantial forced airflow.
All models are tested and specified with external 1 μF paralleled with 10 μF ceramic/tantalum output
capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are
necessary to accommodate our test equipment and may not be required to achieve specified performance
in your applications. However, Murata Power Solutions recommends installation of these capacitors. All
models are stable and regulate within spec under no-load conditions.
(2)
(3)
Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is
Cin=2 x 100 μF tantalum, Cbus=1000 μF electrolytic, Lbus=1 μH.
Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
Deleted
2A
Hiccup autorecovery upon overload
removal. (Note 17)
(4)
www.murata-ps.com
20 Oct 2009
email: sales@murata-ps.com
MDC_OKY_T10T16.D12.A05_long
Page 4 of 17