VR110 Series
Solutions for Intel
®
VRM 11.0
SELECTION GUIDE - STANDARD LOAD LINE
Input Voltage Output Voltage Peak Current
Model
Range (V)
Range (V)
(A)
VR110B150CS-1C
VR110B150CL-1C
150
VR110B150CU-1C 11.04 – 12.60 0.8375 – 1.60
VR110B080CU-1C
80
VR110B080CA-1C
INPUT CHARACTERISTICS - ALL MODELS
Parameter
Conditions
1
Input voltage operating range
Turn-on threshold
Under voltage lockout
Turn-off threshold
VR110B080CA-1C only
Hysteresis voltage
Turn-on threshold
Under voltage lockout
Turn-off threshold
All other models
Hysteresis voltage
Typical: 130A, 1.325VID
Maximum input current
Max: 150A, 1.6VID
No-load input current
Enable state, no load
Recommended input capacitance Sanyo 16SP270M
Disabled input current
Disabled state
On state range
Enable - positive logic
Off state range
Device
Height
2.5” (63.5mm)
1.86” (47.2mm)
1.18” (29.9mm)
1.18” (29.9mm)
0.78” (19.9mm)
Application
Height
2U
1.5U
1U
1U
<1U
MIN.
11.04
TYP.
12.0
9.5
8.2
1.4
5.8
5.0
0.85
15.3
300
2
40
MAX.
12.60
Units
V
V
V
22.4
A
mA
each
mA
DESCRIPTION
The VR110 Series is designed to meet the fast load transients
required by Intel
®
Xeon
®
processors and is fully compliant
with the latest Intel
®
VRM 11.0 specifications. High efficiency
of 84% at full load for reduced power dissipation simplifies
system thermal management. Available in 2U, 1.5U, 1U and
new 0.66U form factors, the VR110 Series is ideal for use in
a wide variety of server applications.
0.9
–0.3
5.0
0.4
V
FEATURES
Intel
®
VRM 11.0 compliant
4 height options 2.5", 1.86", 1.18" and 0.78"
(63.5mm, 47.2mm, 29.9mm and 19.9mm)
DAC programmable output voltage
Power good output signal
Differential remote sense
Remote enable
Supervisory functions
Output overcurrent
Short circuit protection
Overtemperature indicator
Output current level indicator
Tri-state output when disabled
Dynamic VID capability
EN/IEC60950-1 Safety Approval (CB Report)
OUTPUT CHARACTERISTICS - 150A Models
Parameter
Conditions
1
Voltage set point
7-Bit DAC controlled
Line regulation
Load Line
2
Ripple & noise
3
20MHz bandwidth
Current operating range
Efficiency for 11.0 TDC
IO = 130A, VID = 1.325
Turn-on time
V
IN
present: enable to 90% V
OUT
Transient response
4
100A step, 100A/μS, Δ Vo, Adj
5
Compensation range
Remote sense
6
Recommended ceramic
Murata GRM Series or equivalent
Recommended bulk output UCC 4PS560MH11 or equivalent
OUTPUT CHARACTERISTICS - 80A Models
Parameter
Conditions
1
Voltage set point
7-Bit DAC controlled
Line regulation
VR110B080CU-1C
VR110B080CA-1C
Load Line
2
Ripple & noise
3
Current operating range
Efficiency for 11.0 TDC
VR110B080CU-1C
VR110B080CA-1C
Turn-on time
Transient response
4
Remote sense
5
Recommended ceramic
6
Recommended bulk output
20MHz bandwidth
MIN.
0.8375
–2
1.22
0
83
120
TYP.
0
1.25
6.4
84
4
125
50
17
MAX.
1.6
2
1.28
150
10
130
300
Units
V
mV
mΩ
mVp-p
A
%
mS
mV
mV
each
MIN.
0.8375
–2
–4
1.22
0
TYP.
MAX.
1.6
2
3
1.28
80
Units
V
mV
mV
mΩ
mVp-p
A
%
%
0
0
1.25
6.4
IO = 40A, VID = 1.325
IO = 40A, VID = 1.325
V
IN
present: enable to 90% V
OUT
40A step, 100A/μS, Δ Vo, Adj
Compensation range
Murata GRM Series or equivalent
UCC 4PS560MH11 or equivalent
83
86
45
46
10
84
88
4
50
50
17
10
55
300
mS
mV
mV
Each
REG.-Nr. C663
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries
-
email:
sales@murata-ps.com,
tel:
+1 508 339 3000
VR110 Series_B13