UWR Series
Single Output, High Reliability, 2" x 2", 14-20 Watt, DC/DC Converters
~
Performance Specifications and Ordering Guide
Output
Input
Package
(Case,
Efficiency
Min.
R/N (mVp-p)
Regulation (Max.)
VOUT
(Volts)
IOUT
(mA)
VIN Nom.
(Volts)
Range
(Volts)
IIN
Root Model
Typ.
50
50
50
50
50
50
50
50
75
50
75
75
50
75
Max.
100
75
(mA)
Typ.
77%
79%
80%
79%
82%
84%
86%
80%
82%
82.5%
85%
82%
85%
86%
Pinout)
Line
1.0%
0.5%
1.0%
1.0%
0.3%
0.3%
0.3%
1.0%
1.0%
0.3%
0.3%
1.0%
0.3%
0.3%
Load
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
UWR-3.3/4250-D5A
UWR-3.3/4850-D12A
UWR-3.3/4850-D48A
UWR-5/3000-D5A
UWR-5/4000-D12A
UWR-5/4000-D48A
UWR-5/4000-D48E
UWR-5.2/3000-D5A
UWR-12/1250-D5A
UWR-12/1650-D12A
UWR-12/1650-D48A
UWR-15/1000-D5A
UWR-15/1300-D12A
UWR-15/1300-D48A
3.3
3.3
3.3
5
4250
4850
4850
3000
4000
4000
4000
3000
1250
1650
1650
1000
1300
1300
5
4.7-7.5
9-36
80/3720
35/852
15/419
80/3800
15/1020
15/496
15/484
80/3900
80/3660
15/1000
15/491
80/3660
20/967
10/484
76%
77%
79%
78%
81%
82%
84%
79%
80%
79.5%
84%
80%
84%
84%
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
C4, P6
24
48
5
100
100
100
100
100
100
120
100
100
150
100
100
18-75
4.7-7.5
9-36
5
24
48
48
5
5
18-75
36-72
4.7-7.5
4.7-7.5
9-36
5
5.2
12
12
12
15
15
15
5
24
48
5
18-75
4.7-7.5
9-36
24
48
18-75
~ Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise
noted.
Ripple/Noise (R/N) measured over a 20MHz bandwidth.
10% to 100% load.
Nominal line voltage, no-load/full-load conditions.
SeeTechnical Notes for an explanation of trading off input voltage ranges for higher full-power
operating temperature.
These are not complete part numbers. Please see the Part Number Structure.
Part Number Structure
Mechanical Specifications
U WR - 5 / 4000 - D12 A
- C
2.00
(50.80)
RoHS-6 hazardous sub-
stance compliant*
A-Series
High Reliability
Output Configuration:
U = Unipolar
METAL CASE
0.45
(11.43)
Case C4
Wide Range Input
INSULATED BASE
0.040 0.002 DIA.
(1.016 0.051)
Input Voltage Range:
D5 = 4.7-7.5 Volts (5V nominal)
D12 = 9-36 Volts (24V nominal)
D48 = 18-75/36-72 Volts (48V nominal)
Nominal Output Voltage:
3.3, 5, 12 or 15 Volts
0.20 MIN
(5.08)
1.800
(45.72)
0.10
(2.54)
Maximum Output Current
* Contact Murata Power Solutions
in mA
(Datel) for availability.
5
6
7
Temperature Derating
0.200
(5.08)
20
18
16
14
12
10
8
1.200
(30.48)
G
BB
1
2
3
4
2.00
(50.80)
3 EQ. SP. @
0.400 (10.16)
0.400
(10.16)
D
C
E
BB, G
D, E, F
F
8
0.40
(10.16)
A
0.100
(2.54)
AA
B
UWR-3.3/4250-D5A
UWR-3.3/4850-D12A
UWR-3.3/4850-D48A
UWR-5/3000-D5A
F
BOTTOM VIEW
A
A
E
C
B
G
D
E
C
B
E
C
B
I/O Connections
UWR-5/4000-D12A
UWR-5/4000-D48A
UWR-5/4000-D48E
UWR-5.2/3000-D5A
UWR-12/1250-D5A
UWR-12/1650-D12A
UWR-12/1650-D48A
UWR-15/1000-D5A
UWR-15/1300-D12A
UWR-15/1300-D48A
Pin
1
Function P6
+Input
6
Dimensions are in inches (mm shown for ref. only).
2
–Input
4
3
Pin not installed
On/Off Control
Pin not installed
+Output
Third Angle Projection
4
2
5
6
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
7
Common
8
Trim
Ambient Temperature (°C)
Tolerances (unless otherwise specified):
.XX 0.02 (0.5)
.XXX 0.010 (0.25)
Angles 2ꢀ
Notes:
1. UWR-3.3/4850-D48A (18-75V input, curve A) and UWR-3.3/4850-D12A (9-36V input, curve A)
will derate curve AA if used over the limited input ranges of 20-60V or 10-30V, respectively.
For "D5A" and "D12A" models, the
case is connected to pin 2 (–VIN).
For "D48A" and "D48E" models, the
case is connected to pin 1 (+VIN).
2. "D48A" models (18-75V input ranges) that derate along curve B will derate along curve BB
if used over the more limited input range of 24-60V.
Components are shown for reference only.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UWR14-20 Series.B02 Page 2 of 6