 浏览型号MU9C2480L-90DI的Datasheet PDF文件第9页浏览型号MU9C2480L-90DI的Datasheet PDF文件第10页浏览型号MU9C2480L-90DI的Datasheet PDF文件第11页浏览型号MU9C2480L-90DI的Datasheet PDF文件第12页浏览型号MU9C2480L-90DI的Datasheet PDF文件第14页浏览型号MU9C2480L-90DI的Datasheet PDF文件第15页浏览型号MU9C2480L-90DI的Datasheet PDF文件第16页浏览型号MU9C2480L-90DI的Datasheet PDF文件第17页  
Operational Characteristics
LANCAM A/L series (not recommended for new designs)
set in the Control register. During shift rights, bits shifted
off the LSB of the CAM partition reappear at the MSB of
the CAM partition. Likewise, bits shifted off the MSB of
the CAM partition reappear at the LSB during shift lefts.
Mask Registers (MR1, MR2)
The Mask registers can be used in two different ways:
either to mask compares or to mask data writes and moves.
Either Mask register can be selected in the Control register
to mask every compare, or selected by instructions to
participate in data writes or moves to and from Memory. If
a bit in the selected Mask register is set to a 0, the
corresponding bit in the Comparand register enters into a
masked compare operation. If a Mask bit is a 1, the
corresponding bit in the Comparand register does not enter
into a masked compare operation. Bits set to 0 in the Mask
register cause corresponding bits in the destination register
or memory location to be updated when masking data
writes or moves, while a bit set to 1 prevents that bit in the
destination from being changed.
Either the Foreground or Background MR1 can be set
active, but after a reset, the Foreground MR1 is active by
default. MR2 incorporates a sliding mask, where the data
can be replicated one bit at a time to the right or left with
no wrap-around by issuing a Shift Right or Shift Left
instruction. The right and left limits are determined by the
CAM/RAM partitioning set in the Control register. For a
Shift Right the upper limit bit is replicated to the next
lower bit, while for a Shift Left the lower limit bit is
replicated to the next higher bit.
The Memory Array
Memory Organization
The Memory array is organized into 64-bit words with
each word having an additional two validity bits. By
default, all words are configured to be 64 CAM cells.
However, bits 8–6 of the Control register can divide each
word into a CAM field and a RAM field. The RAM field
can be assigned to the least-significant or most-significant
portion of each entry.
The CAM/RAM partitioning is allowed on 16-bit
boundaries, permitting selection of the configuration
shown in Control Register Bits on page 23, bits 8–6 (e.g.,
“001” sets the 48 MSBs to CAM and the 16 LSBs to
RAM). Memory Array bits designated as RAM can be
used to store and retrieve data associated with the CAM
content at the same memory location.
Memory Access
There are two general ways to get data into and out of the
Memory array: directly or by moving the data by means of
the Comparand or Mask registers.
The first way, through direct reads or writes, is set up by
issuing a Set Persistent Destination (SPD) or Set Persistent
Source (SPS) command. The addresses for the direct
access can be supplied directly; supplied from the Address
register, supplied from the Next Free Address register, or
supplied as the Highest-Priority Match address.
Additionally, all the direct writes can be masked by either
Mask register.
The second way is to move data by means of the
Comparand or Mask registers. This is accomplished by
issuing Data Move commands (MOV). Moves using the
Comparand register can also be masked by either of the
Mask registers.
/E
/W
/CM
/EC
DQ15-0
DATA OUT
Figure 6: Read Cycle
Rev. 1
13